PRE-INSTALLATION CHECKS

* When measured from the top of the appliance to the top of the flue, with no horizontal sections

and a maximum of 4 bends with angles of less than 45°

† May be 125mm (5") if burning smokeless or low volatiles fuel only

1. VENTILATION

1.1 This appliance requires ventilation to supply combustion air.

Any room containing the appliance must have a permanent

air vent opening with a total free area of at least 550mm

2

per kW of appliance rated output above 5kW.

1.2 Increase air supply provisions where a room contains

multiple appliances.

1.3 If vents open into adjoining rooms or spaces there must be

an air vent of at least the same size direct to the outside.

1.4 Permanent air vents should be non-adjustable and

positioned where they are unlikely to become blocked.

1.5 Site the vents where cold draught is unlikely to cause

discomfort. This can be avoided by placing vents near

ceilings or close to the appliance, see Diagram opposite.

Without flue liner system Round

(diameter)

Without flue liner system Square

(diameter)

With Liner or Factory made system (diameter)

installed in accordance with manufacturers instructions

All products

Flue/Chimney Size

Flue/Chimney

(*minimum height)

Model

Stockton 7 Inset Convector - Model: 7125

Stockton 8 Inset Convector - Model: 7126

Stockton

7

mm

150

inch

6

mm

150

inch

6

m

4.5

feet

13

mm

135 x 135

inch

5

1/2

x 5

1/2

Stockton

8

150

6

150

6

4.5

13

135 x 135

5

1/2

x 5

1/2

Do not connect to systems containing large voids or over 230mm (9”) square