PRE-INSTALLATION CHECKS

2.2 Extractor fans or cooker hoods must not be placed in the

same room or space as this can cause the appliance to emit

fumes into the room.

2.3 If any of these checks reveal problems do not proceed

with the fitting of the appliance until they have been

rectified.

2. ADDITIONAL VENTILATION

2.1 Additional ventilation is required to comply with the

requirements of the Building Regulations. This must be

provided using a permanently open air vent, of the size

listed, which is positioned so that it is not liable to be

blocked both inside and outside the building.

Model

Stockton 7 Inset Convector - Model: 7125

Stockton 8 Inset Convector - Model: 7126

Stockton

8

Stockton

7

Additional Ventilation

1100

1650

mm2

cm2

in2

11

1.7

16.5

2.56