Notice, Tank pressure regulator – Grizzly H4517 User Manual

Page 12

Advertising
background image

Model H4517/H4518 Air Compressors

-10

-

The pressure regulator has been factory
set for the highest quality operating perfor-
mance.

The pressure regulator ensures the pump
will shut off when the correct PSI is
reached for the air compressor tank.

Tank Pressure

Regulator

Figure 9.

Pressure Regulator

To adjust the pressure regulator:

1.

Unplug the air compressor from
the power supply.

2.

Make sure the compressor switch is in
the

OFF

position.

3.

Drain the pressure from the tank.

4.

Remove the black

ON/OFF

switch

cover by removing the screw which is
in the recess on the top of the cover.
Pull the black cover up and set it
aside.

5.

Turn the pressure adjustment screw
(

Figure 9

) a half turn clockwise to

increase the tank pressure and a half
turn counter-clockwise to decrease
the pressure.

6.

Connect the compressor to the power
supply and start compressor.

7

.

If the PSI level still needs adjustment,
repeat

steps 1 through 6

.

8.

Replace the cover when the proper
adjustments have been made.

NOTICE

The Model H4517/H4518 Air
Compressors have been factory set
to kick off at the proper PSI range.
Only attempt to adjust the pressure
regulator if your air compressor
does not reach or pressurizes
beyond the proper PSI level.

Advertising