Problem cause action – Grizzly H4517 User Manual

Page 18

Advertising
background image

Model H4517/H4518Air Compressors

-16-

Motor runs hot

Pressure relief
valve stays
open and
motor won’t
stop running.

Air leaks from
p r e s s u r e
switch

Air is dirty or
has excessive
moisture.

3. Do not allow the compressor to run over

its recommended duty cycle.

1. Turn compressor off, unplug from power

supply, drain tank. DO NOT USE until
switch is repaired or replaced.

2. Relief valve is relieving pressure too

early, test pressure relief and repair or
replace.

1. Clean dirt or debris from rubber mem-

brane of check valve after removing top
nut.

2. Repair or replace pressure switch.

1. Open drain cocks on both tanks and make

certain all condensation water is drained
out.

2. Remove delivery pipes, clean out and

replace.

PROBLEM

CAUSE

ACTION

3. Compressor is

exceeding its duty-
cycle.

1. Faulty pressure

switch, unit is trying
to overpressure the
tank.

2. Faulty pressure

relief valve.

1. Faulty check valves.

2. faulty pressure

switch.

1. Tank is not drained.

2. Delivery pipes are

dirty.