Installation instructions, Duct fittings, 1 ft – GE JGP656 User Manual

Page 19: 15 ft, 9 ft, 16 ft, 5 ft, 18 ft, 7 ft, 20 ft

Advertising
background image

Total

Equivalent

Number

Equivalent

Duct Pieces

Length*

Used

Length

1 ft.

6

round,

(per foot

straight

length)

feet

1 ft.

3

1

4

x 10

(per foot

straight

length)

feet

6

, 90°

elbow

15 ft.

6

, 45°

elbow

9 ft.

3

1

4

x 10

90° elbow

16 ft.

3

1

4

x 10

45° elbow

5 ft.

3

1

4

x 10

90° flat elbow

18 ft.

6

round

to 3

1

4

x 10

transition

7 ft.

3

1

4

x 10

to 6

round

transition

5 ft.

6

round

to 3

1

4

x 10

transition

90° elbow

20 ft.

3

1

4

x 10

to 6

round

transition

90° elbow

12 ft.

6

round wall

cap with damper

21 ft.

3

1

4

x 10

wall

cap with damper

27 ft.

6

round

roof cap

20 ft.

6

round

roof vent

24 ft.

Total duct run should not exceed 150 ft.

*Actual length of straight duct plus duct fitting equivalent.
Equivalent length of duct pieces are based on actual tests
conducted by GE Evaluation Engineering and reflect
requirements for good venting performance with any
downdraft cooktop.

Installation instructions.

19

Duct Fittings

Use the chart at the right to compute maximum
permissible lengths for duct runs to outdoors.
NOTE: Do not exceed maximum permissible
equivalent lengths!
Flexible ducting:

If flexible metal ducting is used, all the equivalent
feet values in the table should be doubled. The
flexible metal duct should be straight and smooth
and extended as much as possible.
Do NOT use flexible plastic ducting.

NOTE: Any home ventilation system, such as a
cooktop with a downdraft exhaust mechanism, may
interrupt the proper flow of combustion air and
exhaust required by fireplaces, gas furnaces, gas
water heaters and other naturally vented systems.
To minimize the chance of interruption of such
naturally vented systems, follow the heating
equipment manufacturer’s guidelines and safety
standards such as those published by NFPA and
ASHRAE.