S14 Convenient Switches

Installation and User Guide (06/04)

37

www GarrettCom com

.

.

can go temperature uncontrolled environments, rated at –40`C to +75`C. The DC jack is

also present and optionally can be used with an external P-rated AC power supply to

provide “dual source” power input.

DC Power Terminals: “+”, “-”, floating

GND: Terminal for “earth” or ground wire connection to the S14H chassis

Input Voltage:

8 - 15V DC (12V DC)

18 – 36V DC (24V DC)

36 – 60V DC (-48V DC)

Input current:

0.8 amp.(12V DC)

0.4 amp max.(24V DC)