GarrettCom Magnum S14 User Manual

Page 50

Advertising
background image

S14 Convenient Switches

Installation and User Guide (06/04)

43

www GarrettCom com

.

.

Magnum S14-Series units are plug-and-play devices. There is no software

configuring to be done at installation or for maintenance. The only hardware configuration

settings is user options for port#2, to configure at FF/AN and can be done through a manual

switch accessed from the front side. The internal functions of both are described below.

Switching, Filtering and Forwarding

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses on

the same port segment will be filtered, constraining them to one port and relieving the rest

of the network from processing them. A packet whose destination address is on another

port segment will be forwarded to the appropriate port, and will not be sent to the other

ports where it is not needed. Packets needed for maintaining the operation of the network

(such as occasional multi-cast packets) are forwarded to all ports.

Advertising