Installation Instructions

8

7 INSTALL DUCT COVERS AND

UTILITY BARS

• Separate the duct covers supplied with the hood.
• Discard the upper (inner) section.
• Insert the ZXR758 or ZXR7510 duct cover (with

vent holes) into the original lower section. Be sure
that the new duct section is inside the shorter
original section.

• Place the decorative duct covers on top of the hood.
• Insert the lower portion of the duct cover into the

impressions on the top of the hood.

• Extend the inner duct upwards to meet the ceiling

and support frame.

• Secure the duct cover to the frame with the 2 small

Phillips screws provided.

• Install the side utility bars as shown with screws

provided.

6 CONNECT ELECTRICAL

• Verify that power is turned off at the source.

WARNING:

If house wiring is not 2-wire

with a ground wire, a ground must be provided by
the installer. When house wiring is aluminum, be
sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.

• Insert house wiring through strain relief and

tighten.

• Connect white leads to branch circuit white lead.
• Connect black leads to branch circuit black lead.
• Connect green/yellow leads to branch circuit green

lead or bare ground lead.

• Secure all connections with wire nuts on each

electrical connector.

• Push wires into junction box and replace cover.

Be sure wires are not pinched.

Mounting Screw Holes