10. Attach limit switch wires.

Uncoil limit switch wires.

Place into channels located along top of rail.

Run wires back to power head through hole in top
of power head (Fig. 1-12).

Use wire clips to hold wires in place (Fig. 1-13).

Attach limit switch wires to terminals on power
head (Fig. 1-14).

White wire (“OPEN”) to terminals #4 and #5.

Brown wire (“CLOSE”) to terminals #5 and #6.

Bundle extra wire and lay it on top of power head
(Fig. 1-14 inset).

9. Attach limit switches.

2 switches included, “CLOSE” limit switch (brown
wire) and “OPEN” limit switch (white wire)
(Fig. 1-10).

Turn set screws (39) into threaded holes, just
enough so screw stays in place. (Fig. 1-10).

Point arrow on top “CLOSE” limit switch toward
door end of rail.

Place “CLOSE” limit switch (Brown wire) on rail
about 12” from rail strap (Fig. 1-11).

Gently tighten set screw enough to keep switch
from moving.

Point arrow on top “OPEN” limit switch toward
door end of rail.

Place “OPEN” limit switch (white wire) on rail
where chain attaches to carriage slide. (Near
the power head.)

Gently tighten set screw enough to keep switch
from moving.

FIG. 1-10 Identify limit switches / insert set screws.

FIG. 1-11 Place limit switches.

FIG. 1-13 Wire clips.

FIG. 1-12 Run wire to power head.

FIG. 1-14 Attach wire at power head terminals.

[39]

[41]

Bundle