-9-

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

110/220V Operation

SECTION 2: CIRCUIT REQUIREMENTS

Amperage Draw

The Model G1005Z features a 110/220V motor
that is prewired for 110V and draws the following
amps under maximum load:

Motor Draw at 110V ............................... 12 Amps
Motor Draw at 220V ................................6 Amps

Circuit Requirements

We recommend using a dedicated circuit for this
machine. You MUST connect your machine to a
grounded circuit that is rated for the amperage
given below. Never replace a circuit breaker on
an existing circuit with one of higher amper-
age without consulting a qualified electrician to
ensure compliance with wiring codes.

If you are

unsure about the wiring codes in your area or

you plan to connect your machine to a shared

circuit, consult a qualified electrician.

110V Circuit ...........................................15 Amps
220V Circuit ...........................................15 Amps

Figure 2. NEMA 6-15 plug and outlet.

Plug Type

The Model G1005Z comes prewired with a NEMA
5-15 plug. If you wish to rewire the motor to 220V
we recommend using the following plug (see
Figure 2 for an example):

220V Plug & Receptacle ...................NEMA 6-15