Recommended relubrication frequency in months – Greenheck Fan Centrifugal Sidewall Exhaust Fans CW/CWB User Manual

Page 7

Advertising
background image

7

Model CW/CWB • Centrifugal Sidewall Exhaust Fans

®

Table 3: Grease Manufacturers

Manufacturer

Grease (NLGI #2)

U.S. Electric Motors

Grease No. 83343

Chevron U.S.A. Inc

Chevron SRI Grease #2

Mobil Oil Corporation

Mobilith
Mobil 532

Texaco, Inc.

Premium BRB #2
Texaco Multifak #2

Amoco Oil Co.

Rykon Premium #2

Exxon

Unirex N2

Shell

B Shell Alvania #2

Table 2: Suggested Fan Bearing Greasing Intervals

Interval

(months)

Type of Service

1 to 3

Heavy duty in dirty, dusty locations; high ambient

temperatures; moisture laden atmosphere;

vibration.

3 to 6

12 to 24 hours per day, heavy duty, or if moisture

is present

6 to 12

8 to 16 hours per day in clean, relatively dry

atmosphere

12 to 18

Infrequent operation or light duty in clean

atmosphere

Recommended Relubrication

Frequency in Months

NOTE: If unusual environment conditions exist
(extreme temperature, moisture or contaminants) more
frequent lubrication is required.
A good quality lithium base grease, conforming to
NLGI Grade 2 consistency, such as those listed here
may be used.

CW Direct Drive Centrifugal Sidewall Exhaust Fan

Parts List

NOTE
Each fan bears a manufacturer’s nameplate with model number and serial number embossed. This information will as-

sist the local Greenheck representative and the factory in providing service and replacement parts. Before taking any

corrective action, make certain unit is not capable of operation during repairs.
CAUTION
A fan manufactured with an explosion resistant motor does not certify the entire unit to be explosion proof.

Mounting Plate

Windband

Birdscreen

Breather Tube

Motor Compartment

Wheel

Cover

Advertising