Installation instructions, Installing the cooktop, Warning – GE 49-80388 12-05 JR User Manual

Page 28

Advertising
background image

BLOWER ELECTRICAL
CONNECTIONS

Loosen the two screws and remove and discard the

sheet metal connector cover on the cooktop bottom.
Save the screws for reinstallation later.

Connect the 5-pin plug on the blower assembly to

the matching 5-pin receptacle on the bottom of the
cooktop.

Fold all wires into the electrical enclosure. Secure

the enclosure with the screws removed earlier,
making sure that no wires are trapped.

Plug the cooktop cord set into a suitable electrical

outlet. See step 17.

16

Installation Instructions

INSTALLING THE COOKTOP

INSTALL THE PRESSURE
REGULATOR

Install the supplied pressure regulator in the gas line

as close to the cooktop inlet as possible. Allowances
for ventilation ducting may be necessary.
Make sure the regulator is installed in the right
direction.

Install a manual shut-off valve in the gas line in an

easily accessible location.
NOTE: Instead of using solid piping to connect to
pressure regulator, an approved flexible metal
appliance connector may be used between the
shut-off valve and the pressure regulator, if local
codes permit.
Appropriate flare nuts and adapters are required at
each end of the flexible connector.

TEST FOR LEAKS

WARNING:

DO NOT USE A FLAME TO CHECK

FOR GAS LEAKS! Do not use the cooktop until all
connections have been leak tested.
Perform leak test per the following instructions:
1.
Purchase a liquid leak detector or prepare a soap

solution of one part water, one part liquid detergent.

2. When all connections have been made, make sure

all cooktop controls are turned to OFF and turn the
gas supply valve to ON.

3. Apply the liquid leak detector or the soap solution

around all connections from the shut-off valve to the
cooktop.

4. A leak is identified by a flow of bubbles from the

area of the leak.

5. If a leak is detected, turn the gas supply off. Tighten

the fitting. Turn the gas on and test again.
If the leak persists, turn the gas supply off and
contact your dealer for assistance. Do not attempt to
operate the cooktop if a leak is present.

Regulator

Solid piping or
flexible connector

Union

Pipe stub

Shut-off

valve

15

Solid piping
or flexible
connector

5-pin
connectors

Electrical
enclosure

Flexible
conduit

INSTALL THE PRESSURE
REGULATOR (cont.)

IMPORTANT: Disconnect the cooktop and the
individual shut-off valve from the gas supply piping
system during any pressure testing of that system
at test pressures greater than 1/2 psig. Isolate the
cooktop from the gas supply piping system by
closing the individual manual shut-off valve to the
cooktop during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1/2 psig.

15

5-pin
connectors

28