Setting up paging alerts

To set up paging alerts:

1

Boot your server from the Server Companion CD, then select

System Setup

Utility

from the menu. The System Setup Utility starts.

2

Install an external modem on the serial RJ-45 port on the back of your
server.

3

In the SSU Main window, click

Platform Event Manager (PEM)

.

4

In the PEM window, click

Configure EMP

.

5

In the corresponding boxes, enter the following command strings for the
modem attached to the serial RJ-45 port:

■

ESC Sequence

—The escape sequence. This string is sent to the modem

before sending command strings. The maximum length for the string
is five characters. Longer strings are truncated.

■

Hangup String

—Hang up or drop the connection. The EMP

automatically sends an E

NTER

character following this string. The

maximum length for the string is eight characters.

■

Modem Dial Command

—The command to dial a phone number. This

string is sent to the modem before sending the paging string.

■

Modem Init String

—Initialization string for the modem. Sent every time

the EMP initializes. You will be notified if the string is truncated.
Following a save, the actual string saved is displayed in the edit box.

6

Click

Save

to save the changes.

7

Click

Close

to return to the PEM window.

8

In the PEM window, click

Configure PEP

.

9

Click to select the

Enable PEP

check box.

10

In the

Blackout Period

box, type the minimum time, in minutes, between

successive pages. The valid range is 0-255 where 0 disables the blackout
period.

Setting a blackout period can save you from being flooded with repeat
pages. After you receive a PEP page, no additional pages are sent by PEP
for the duration of the blackout period.