7

Install motor slide caps
7. Position the caps as shown at right so that

the grooves in the slide cap are aligned with
the grooves in the motor.

8. Apply straight downward pressure to each

end of the cap while sliding into the closed
position.

9. Repeat step 8 for the other cap.
10. Ensure that all four corners of each slide cap

are engaged.

WARNING: Ensure that the motor is assem-

bled on bed as instructed above before use.

Motor assembly troubleshooting
Problems associated with improper motor installation are listed below, with appropriate fix.

Problem

Probable cause

Fix

Head operates with knee control button and

knee operates with head control button

Motor is installed backwards

Remove motor and reverse it (see previ-

ous page)

Knee lifting linkages bind against grid

deck, preventing knee deck from elevating.

Motor is installed backwards, enabling

knee to elevate too high and bind linkage

Remove motor and reverse it (see previ-

ous page)

motor

slide cap

Install motor slide caps

pressure

Advertising