IMPORTANT:

REFER TO DATA BADGE AND TECHNICAL

SPECIFICATION AT THE FRONT OF THE MANUAL TO

ENSURE THE APPLIANCE IS CORRECTLY ADJUSTED FOR

THE GAS TYPE AND CATEGORY APPLIED IN THE

COUNTRY OF USE.

FOR DETAILS OF CHANGING BETWEEN GAS TYPES

REFER TO SECTION 10, SERVICING, ‘REPLACING PARTS’.

1. SAFETY PRECAUTIONS

1.1 For your own and other’s safety, you must install this

appliance according to local and national codes of practice.

Failure to install the stove correctly could lead to

prosecution:

• Read these instructions before installing and using this

stove.

1.2 These instructions must be left intact with the user.
1.3 Do not attempt to burn rubbish on this appliance.
1.4 Keep all plastic bags away from young children.
1.5 Do not place any object on or near to the appliance and

allow adequate clearance above the appliance.

IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN

USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO

RELIGHT THE APPLIANCE.

2. INSTALLATION OF THE APPLIANCE

1.1 This appliance can be installed in four different ways:

1) Builder’s opening with a frame

2) Builder’s opening without a frame

3) Stud work with a frame

4) Stud work without a frame


Where no frame is used an edge kit is available to enable

the installer to plaster to a finished edge: Kit No. 8727

CFFK01 for Studio 1 and 8727 CFFK02 for Studio 2

Options 1) and 2) above can be:

• top exit with a liner

• rear exit without a liner

1.2 The Studio is supplied with a flue fixing plate to attach the

flue to the appliance within the aperture, Diagram 1.

AR1010

1

When installing the appliance into a masonry chimney

without a liner, it must be converted to a rear exit:

• Remove the two fixing screws securing the spigot

assembly

• Slide the blanking plate into the guides

• Replace the two fixing screws, Diagram 2

AR2007

2

The flue must be in good condition and clear products of

combustion, see Commissioning)

Option 3) and 4) must be fitted using the top exit only with

rigid twin wall flue pipe.

THE APPLIANCE IS SUPPLIED WITH A WALL BOX

CONTAINING THE BATTERIES AND TOUCH PAD. THIS

MUST BE RECESSED INTO THE WALL WITH ACCESS

FOR THE CABLES PRIOR TO FITTING THE APPLIANCE.

2.1 Remove the appliance from the carton and discard all

unnecessary packaging. Ensure no components are thrown

away when unpacking.

2.2 To access the controls and gas inlet:

• Remove the glass door, enamelled liners, burner and

splitter plate. See Section 4

2.3 The gas supply enters the fire through a silicon panel on the

floor under the access panel, Diagram 3:

• Slit with a sharp knife before bringing through the supply

pipe, Diagram 1

INSTALLATION INSTRUCTIONS

INSTALLATION

Advertising