Servicing instructions, Replacing parts, Gas valve – Stovax STUDIO 8700CFCHEC User Manual

Page 28: Magnetic safety valve, Control box

Advertising
background image

28

SERVICING INSTRUCTIONS

REPLACING PARTS

10. GAS VALVE

10.1 To change the gas valve:

• Disconnect the inlet pipe

• Disconnect the feed pipe

• Disconnect the pilot pipe

• Disconnect the thermocouple, thermo current wires and

the interrupter block

• Remove the two screws and rotate the valve to

access the front

The cable can now be removed from the valve, Diagram 13

13

AR1963

• Reassemble in reverse order and check for leaks

11. MAGNETIC SAFETY VALVE

11.1 To replace the magnetic safety valve:

• Undo the thermocouple from the interrupter block and

remove the two thermo current cables

• Unscrew the interrupter block from the back of the valve

• Undo the silver magnetic valve retaining nut on the back

of the valve.

• Gently tap out the mag valve

• Replace with a new unit

• Reassemble in reverse order

• Check for leaks

12. CONTROL BOX

• Remove the cover fixing screw, Diagram 14

14

AR1963

• Remove the two thermo current cables by removing the

two screws, Diagram 15

• Remove the ignition lead, Diagram 15

• Remove the eight loom wire from the control box,

Diagram 15

15

AR1915

Touch pad
extension
cable

Battery
extension
cable

Eight wire
cable

Thermo current
cables

Ignition lead

• Remove the battery extension cable, Diagram 15

• Remove the touch pad extension cable

The control box can now be replaced.

After replacing the control box you may need to reprogram

the handset:

• Press and hold the reset button on the control box until

you hear two signals. After the second longer signal:

Release the reset button and within 20

seconds

Press the DOWN button on the handset until

you hear an additional long signal

confirming the new code

• Refer to separate handset instructions to set new code

Advertising