5-6

Panel C Industrial Computer Hardware User's Manual

– May 2003

GFK-2251

5

Control and Status LEDs

The Panel C industrial computer includes five status LEDs, located in a vertical column
above the arrow keys on the lower right-hand side of the unit. The five LEDs have the
following functions, in order from top to bottom:

Table 5-2. Indicators

Symbol

Name

Function

F

FF

FN

N

N

N

Function Key

Indicates the function key is active.

Shift

Indicates the Shift lock is enabled..

HDD/Error

This is a tri-color LED. Red indicates a BIOS detected error. Green is
the normal IDE drive activity indicator. During an error the HDD/Error
LED will be Amber.

Power

Indicates system power (lighted when power is applied).

Compact
Flash

Indicates Compact Flash card is inserted.

Touch Screen

The Panel C includes a resistive overlay touch screen on the flat panel display.

The touch screen has a resolution of 1024 x 1024 touch points (independent of screen
size) and provides an efficient and reliable method of entering information. The screen
responds to the touch of your finger with or without a glove.

The touch screen is connected internally to the COM3 serial port. If you install a card that
has settings that conflict with those of the COM3 serial port, you will need to change the
card’s configuration.

Touch Screen Driver for Windows

The integral touch screen of the Panel C is internally connected to COM3. Parameters
must be set within the driver so that they match the hardware settings. The factory default
settings are:

COM Port = 3
Address = 3F8 Hex
Interrupt = Com3 IRQ 9

These parameters are written into the system registry file by the driver setup utility. The
driver is installed, configured and calibrated at the time of manufacture.