background image

Motor Control Board

12

3A0246C

Motor Control Board

Removal

120V Models:

1.

Perform Pressure Relief Procedure, see page 4.
Wait 5 minutes before servicing.

2.

Remove Power Module, see page 7.

3.

Disconnect material hose (79) from pump (18a).

4.

Remove four screws (40) and lift motor shroud (98)
off of motor.

5.

Remove four screws (33b) and display cover (33k).

6.

Disconnect display connector (A) from motor control
board (24) and remove display.

7.

Remove bottom two screws (61) and remove control
panel (37).

8.

Disconnect Prime/Tool Fill/Recirculate reed switch
connector (E) from motor control board (24).

9.

Disconnect potentiometer connector (C) from motor
control board (24).

10. Disconnect 15/20A switch connector (X) from motor

control board (24).