Pressure Transducer

3A0246C

21

Pressure Transducer

Removal

1.

Perform Pressure Relief Procedure, see page 4.
Wait 5 minutes before servicing.

2.

Remove four screws (33b) and cover (33k).

3.

Disconnect transducer connector (E) from motor
control board (24).

4.

Disconnect potentiometer connector (D) and reed
switch connector (87) from motor control board (24).

5.

Remove four screws (61) and control box (3). Allow
control panel (37) to hang down freely.

6.

Remove grommet (23) from control box (3).

7.

Remove transducer (39) and o-ring (50) from mani-
fold (70). Remove grommet (23) from transducer
and save for reuse.

Installation

1.

Install o-ring (50) and transducer (39) in manifold
(70). Torque to 35-45 ft-lb (47-61 N•m). Install grom-
met onto transducer (39) and transducer into control
box (3).

33k

33b

ti15786a

24

E

ti12999a

87

24

D

ti15792a

61

37

3

61

ti15797a

ti15795a

3

23

ti15785a

23

39

50

70

ti15788a

3

70

50

39