Flow Control Adjust Potentiometer

3A0246C

23

Flow Control Adjust
Potentiometer

Removal

1.

Perform Pressure Relief Procedure, see page 4.
Wait 5 minutes before servicing.

2.

Remove four screws (33b) and cover (33k).

3.

Remove bottom two screws (61) and remove control
panel (37).

4.

Disconnect potentiometer connector (D) from motor
control board (24).

5.

Use hex wrench to remove control knob (42).

6.

Remove gasket (56), nut, spacer (88) and potenti-
ometer (55) from control panel (37).

Installation

1.

Install gasket (56), nut, spacer (88) and potentiome-
ter (55) on control panel (37). Torque nut to 30-35
in-lb (3.25-4.0 N•m).

2.

Install control knob (42): Check control knob align-
ment to potentiometer shaft. Turn shaft fully clock-
wise and attach knob in full ON position with a hex
wrench. Make sure set screw is tightened flat
against potentiometer shaft.

3.

Connect potentiometer connector (D) to motor con-
trol board (24).

33b

33k

ti15786a

ti15795a

37

61

D

24

ti15791a

42

ti7258a

88

56

37

55

ti15794a

88

56

37

55

ti15794a

42

ti13338a

24

D

ti15791a