Inline Valve

Changing the Needle

Removal

NOTE: Needle (404b), housing/seat (404c), and o-ring
(404a) must be replaced together. They are included in
repair kit 24F263.

1.

Perform Pressure Relief Procedure, see page 4.

2.

Squeeze trigger while unscrewing housing/seat
(404c) and o-ring (404a).

3.

Remove trigger stop (420) with hex wrench.

4.

Remove locknut (414) and bracket (413).

5.

Tap rear of inline valve with a plastic mallet and
punch to push needle assembly (404b) out through
front of housing (401).

Installation

1.

Guide threaded end of needle assembly (404b) into
front of housing (401).

2.

Install bracket (413) and locknut (414) loosely on
threaded end of needle (404b). Squeeze trigger to
pull needle assembly into housing (401).

3.

Squeeze trigger while installing o-ring (404a) and
housing/seat (404c). Torque housing/seat to 26-32
ft-lb (35-43 N•m).

4.

Adjust needle before using inline valve.

404c

404a

404b

ti15626a

ti15810a

420

ti15862a

413

414

ti15811a

401

404b

ti15809a

401

404b

ti15804a

414

413

ti15806a

404c

404a

404b

ti15626a

t15805Xa