BusSecure User Manual

Troubleshooting

0150-0263A / May 2003

29

5

T

ROUBLESHOOTING

F

ACTORY

S

ETTINGS

:

To reset the factory settings, remove the cover panel
and hold down the indicated button (

) for 5 seconds.

This action will restore the default IP address to
3.18.173.0.

O

PTIONAL STATUS LIGHTS

:

The status lights will alert you to the status of the DVR. DVR status lights should not be confused with
DVR LEDs. The LEDs are located on the front of the removable DVR unit. The term status lights is used
to refer to any lights or LEDs connected to the two outputs from the DVR, such as the BusSecure Panic
Button. Status lights can be mounted anywhere depending upon the installation and are optional devices.

Note: Some properties customize the DVR status outputs and use another device (such as an IO or PLC) to control the lights.

Output 1 corresponds to Check System and Output 2 corresponds to Normal.

Output 2: the DVR is running and capturing images.

Output 1 and 2: the DVR is running and capturing images with an exception (e.g., loss of signal
from a camera). Check the Recorder Log of the DVR to investigate further.

Output 1: the DVR has encountered an error and is not capturing images.

No lights: the DVR is not running.

P

OSSIBLE CAUSES FOR A

“C

HECK

S

YSTEM

STATUS LIGHT ON

(in conjunction with a normal status light if

installed):

Camera failure

Camera enabled but not installed

Event data deleted before the configured minimum time has passed

Surveillance data deleted before the configured minimum time has passed

BusSecure

Figure 31. Location of factory reset button