Expanded heating data, Xpanded, Eating – Goodman Mfg GPH14H User Manual

Page 17: Roduct, Pecifications

Advertising
background image

P

roduct

S

PecificationS

P

roduct

S

PecificationS

SS-GPH14H

www.goodmanmfg.com

17

e

xPanded

H

eatinG

d

ata

GPH1424H41**

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

28.7

27.1

25.5

23.9

22.8

22.1

20.5

18.9

16.2

15.0

13.8

13.0

12.5

11.2

10.0

8.7

7.4

6.1

T/R

31.2

29.6

27.8

26.0

24.8

24.1

22.4

20.6

17.6

16.3

15.0

14.2

13.6

12.2

10.8

9.5

8.1

6.6

kW

1.86

1.82

1.78

1.75

1.73

1.71

1.67

1.63

1.65

1.61

1.58

1.55

1.54

1.50

1.46

1.42

1.38

1.34

Amps

9.1

8.4

7.9

7.5

7.2

7.1

6.7

6.4

6.2

5.9

5.6

5.5

5.5

5.2

4.9

4.6

4.3

3.9

COP

4.51

4.36

4.19

4.00

3.87

3.78

3.59

3.39

2.87

2.71

2.56

2.45

2.38

2.19

2.00

1.79

1.57

1.32

EER

15.4

14.9

14.3

13.7

13.2

12.9

12.3

11.6

9.8

9.3

8.7

8.4

8.1

7.5

6.8

6.1

5.4

4.5

HI PR

367

352

338

324

316

310

298

286

274

262

251

245

241

232

223

214

206

199

LO PR

142

132

123

113

107

103

95

84

76

68

60

56

54

45

39

33

29

23

GPH1430H41**

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

34.7

32.8

30.9

28.9

27.6

26.7

24.8

22.9

19.2

17.7

16.3

15.4

14.8

13.3

11.8

10.3

8.8

7.2

T/R

30.6

29.0

27.3

25.5

24.3

23.6

21.9

20.2

16.9

15.6

14.4

13.6

13.1

11.7

10.4

9.1

7.7

6.3

kW

2.26

2.22

2.17

2.13

2.10

2.08

2.04

1.99

1.98

1.93

1.89

1.86

1.84

1.79

1.75

1.70

1.66

1.61

Amps

11.0

10.3

9.7

9.1

8.8

8.7

8.2

7.8

7.5

7.2

6.9

6.8

6.7

6.4

6.0

5.7

5.3

4.9

COP

4.48

4.33

4.16

3.97

3.84

3.76

3.56

3.36

2.84

2.68

2.53

2.42

2.36

2.17

1.97

1.77

1.55

1.30

EER

15.3

14.8

14.2

13.6

13.1

12.8

12.2

11.5

9.7

9.2

8.6

8.3

8.1

7.4

6.7

6.0

5.3

4.5

HI PR

374

359

345

330

322

316

304

291

279

267

256

250

245

236

227

218

210

203

LO PR

134

124

117

107

101

97

89

80

72

64

56

52

51

43

37

31

27

21

GPH1436H41**

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

41.5

39.3

37.0

34.6

33.0

32.0

29.7

27.4

26.9

24.8

22.9

21.6

20.8

18.7

16.5

14.4

12.3

10.1

T/R

32.0

30.3

28.5

26.7

25.5

24.7

22.9

21.1

20.8

19.2

17.7

16.7

16.1

14.4

12.8

11.1

9.5

7.8

kW

2.74

2.68

2.63

2.57

2.54

2.52

2.47

2.41

2.64

2.58

2.52

2.48

2.46

2.39

2.33

2.27

2.21

2.15

Amps

13.5

12.6

11.9

11.2

10.9

10.7

10.1

9.7

9.3

8.9

8.5

8.4

8.3

7.9

7.4

7.1

6.6

6.1

COP

4.44

4.29

4.12

3.93

3.80

3.71

3.52

3.32

2.98

2.82

2.66

2.55

2.48

2.28

2.08

1.86

1.63

1.37

EER

15.2

14.6

14.1

13.4

13.0

12.7

12.0

11.4

10.2

9.6

9.1

8.7

8.5

7.8

7.1

6.4

5.6

4.7

HI PR

367

352

338

323

316

310

298

286

274

262

251

245

241

232

223

214

206

199

LO PR

135

125

117

108

102

98

90

80

72

65

57

53

51

43

37

31

27

21

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

kW = Total system power

High pressure is measured at the liquid line access fitting.

Low pressure is measured at the compressor suction access fitting.

Amps: Unit amps (comp.+ evaporator motor + condenser fan motor)

Advertising