P

roduct

S

PecificationS

P

roduct

S

PecificationS

18 www.goodmanmfg.com

SS-GPH14H

e

xPanded

H

eatinG

d

ata

(

cont

.)

GPH1442H41**

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

47.1

44.6

42.0

39.3

37.5

36.3

33.8

31.1

26.7

24.6

22.7

21.4

20.6

18.5

16.4

14.3

12.2

10.0

T/R

33.6

31.8

29.9

28.0

26.7

25.9

24.0

22.2

19.0

17.5

16.1

15.2

14.7

13.2

11.7

10.2

8.7

7.1

kW

3.07

3.01

2.95

2.89

2.85

2.83

2.77

2.71

2.39

2.33

2.28

2.25

2.23

2.18

2.12

2.07

2.02

1.97

Amps

12.5

11.6

10.9

10.3

9.9

9.8

9.2

8.8

8.4

8.1

7.7

7.5

7.5

7.1

6.7

6.3

5.9

5.3

COP

4.50

4.34

4.17

3.98

3.85

3.76

3.57

3.36

3.27

3.09

2.91

2.78

2.71

2.49

2.26

2.02

1.77

1.49

EER

15.4

14.8

14.2

13.6

13.1

12.9

12.2

11.5

11.2

10.5

9.9

9.5

9.2

8.5

7.7

6.9

6.0

5.1

HI PR

370

355

341

326

319

313

301

288

276

264

253

247

243

234

225

215

208

200

LO PR

137

127

119

109

103

99

91

81

73

65

58

54

52

44

38

32

28

22

GPH1448H41**

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

56.6

53.6

50.4

47.1

45.0

43.6

40.5

37.4

32.4

29.9

27.5

26.0

25.0

22.5

19.9

17.4

14.8

12.1

T/R

32.7

31.0

29.2

27.3

26.0

25.2

23.4

21.6

18.7

17.3

15.9

15.0

14.5

13.0

11.5

10.1

8.6

7.0

kW

3.61

3.54

3.47

3.40

3.36

3.33

3.26

3.19

3.17

3.10

3.03

2.99

2.96

2.89

2.82

2.75

2.67

2.60

Amps

18.5

17.2

16.2

15.4

14.9

14.6

13.8

13.2

12.7

12.2

11.7

11.5

11.3

10.8

10.2

9.7

9.1

8.3

COP

4.59

4.43

4.25

4.06

3.92

3.84

3.64

3.43

2.99

2.82

2.66

2.55

2.48

2.28

2.07

1.85

1.62

1.37

EER

15.7

15.1

14.5

13.9

13.4

13.1

12.4

11.7

10.2

9.6

9.1

8.7

8.5

7.8

7.1

6.3

5.5

4.7

HI PR

383

368

353

338

330

324

311

299

286

273

262

256

251

242

233

223

215

208

LO PR

135

126

118

108

102

98

90

80

73

65

57

53

51

43

37

31

27

22

GPH1460H41**

Outdoor Ambient Temperature

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

68.5

64.9

61.0

57.1

54.5

52.8

49.1

45.2

42.1

38.9

35.8

33.8

32.5

29.2

25.9

22.6

19.3

15.8

T/R

39.6

37.5

35.3

33.0

31.5

30.6

28.4

26.2

24.4

22.5

20.7

19.6

18.8

16.9

15.0

13.1

11.1

9.1

kW

4.76

4.67

4.57

4.47

4.41

4.37

4.28

4.18

4.08

3.98

3.88

3.83

3.79

3.69

3.59

3.50

3.40

3.30

Amps

23.9

22.2

20.9

19.7

19.0

18.7

17.7

16.8

16.1

15.4

14.8

14.4

14.2

13.6

12.7

12.0

11.2

10.2

COP

4.21

4.07

3.91

3.74

3.61

3.54

3.36

3.17

3.02

2.86

2.70

2.58

2.51

2.32

2.11

1.89

1.66

1.40

EER

14.4

13.9

13.4

12.8

12.3

12.1

11.5

10.8

10.3

9.8

9.2

8.8

8.6

7.9

7.2

6.5

5.7

4.8

HI PR

407

390

375

358

350

343

330

317

303

290

278

272

267

257

247

237

228

220

LO PR

130

121

113

104

98

94

87

77

70

62

55

51

49

41

36

30

26

21

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

kW = Total system power

High pressure is measured at the liquid line access fitting.

Low pressure is measured at the compressor suction access fitting.

Amps: Unit amps (comp.+ evaporator motor + condenser fan motor)

Advertising