Product specs, Roduct, Pecifications – Goodman Mfg GPH14H User Manual

Page 3

Advertising
background image

P

roduct

S

PecificationS

P

roduct

S

PecificationS

SS-GPH14H

www.goodmanmfg.com

3

S

pecificationS

GPH14

24H41A*

GPH14

24H41C*

GPH14

30H41A*

GPH14

30H41C*

GPH14

36H41A*

GPH14

36H41C*

Cooling Capacity

AHRI Cooling Capacity (BTU/h)

24,000

24,000

28,400

28,400

36,000

36,000

Sensible BTU/h

18,200

18,200

23,400

23,400

27,400

27,400

SEER / EER

14.5 / 12.0

14.5 / 12.0

14.0 / 12.0

14.0 / 12.0

14.0 / 11.5

14.0 / 11.5

Decibels

76

76

76

76

78

78

AHRI Numbers

4385132

5677874

4385133

5677875

4385134

5677876

Heating Capacity
BTU/h (47°F)

22,800

22,800

27,600

27,600

32,200

32,200

C.O.P. (47°F)

3.8

3.8

3.8

3.8

3.7

3.7

BTU/h (17°F)

13,000

13,000

15,400

15,400

20,400

20,400

C.O.P. (17°F)

2.4

2.4

2.5

2.5

2.4

2.4

HSPF

8.0

8.0

8.0

8.0

8.0

8.0

Evaporator Motor

Type

EEM

EEM

EEM

EEM

EEM

EEM

Wheel (D x W)

10 x 8

10 x 8

10 x 8

10 x 8

10 x 8

10 x 8

Cooling CFM

875

875

1,050

1,050

1,200

1,200

Fan-Only CFM

800

800

950

950

1,100

1,100

RLA

1.5

1.5

1.86

1.86

1.86

1.86

No. of Speeds

5

5

5

5

5

5

Horsepower - RPM

½ - 1,050

½ - 1,050

½ - 1,050

½ - 1,050

½ - 1,050

½ - 1,050

Evaporator Coil
Face Area (ft

2

)

5.25

5.2

4.67

5.2

5.2

6.2

Rows Deep/ Fins per Inch

3/ 16

3/ 14

4/ 16

3/ 14

3/ 14

3/ 14

Indoor Metering Device Size

0.057

0.061

0.065

0.065

0.068

0.068

Filter Size (ft

2

)

20 x 20 x 1

20 x 20 x 1

20 x 25 x 1

20 x 25 x 1

25 x 25 x 1

25 x 25 x 1

Drain Size (NPT)

¾"

¾"

¾"

¾"

¾"

¾"

Refrigerant Charge (oz.)

85

105

105

105

125

125

Condenser Fan / Coil
Horsepower - RPM

1/6 - 815

1/6 - 815

1/6 - 815

1/6 - 815

¼ - 1075

¼ - 1075

RLA/LRA

1.1 / 1.7

1.1 / 1.7

1.1 / 1.7

1.1 / 1.7

1.5 /3.0

1.5 /3.0

Fan Diameter / # Fan Blades

22 / 3

22 / 3

22 / 3

22 / 3

22 / 4

22 / 4

Face Area (ft

2

)

13.4

13.4

13.4

13.4

17

17

Outdoor Metering Device Size

0.049

0.047

0.047

0.047

0.067

0.063

Rows Deep/ Fins per Inch

1 / 24

1 / 24

1 / 24

1 / 24

1 / 24

1 / 24

Compressor
Quantity / Type

1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single

Compressor RLA/LRA

12.8 / 58.3

12.8 / 58.3

14.1 / 73

14.1 / 73

16.7 / 79

16.7 / 79

Electrical Data
Voltage/Phase/ Frequency

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

Indoor Blower FLA

1.5

1.5

1.86

1.86

1.86

1.86

Outdoor Fan RLA

1.1

1.1

1.1

1.1

1.4

1.4

Total Unit Amps

15.4

15.4

17.06

17.06

19.96

19.96

Min. Circuit Ampacity¹

18.6

18.6

20.6

20.6

24.2

24.2

Min. Overcurrent Protection (amps)²

30

30

30

30

40

40

Operating & Ship Weights (lbs)

315 / 325

315 / 325

315 / 325

315 / 325

375 / 385

375 / 385

¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Note: Always check the S&R plate for electrical data on the unit being installed.