Cont, Roduct, Pecifications – Goodman Mfg GPH14H User Manual

Page 4

Advertising
background image

P

roduct

S

PecificationS

P

roduct

S

PecificationS

4 www.goodmanmfg.com

SS-GPH14H

S

pecificationS

(

cont

.)

GPH14

42H41A*

GPH14

42H41C*

GPH14

48H41A*

GPH14

48H41C*

GPH14

60H41A*

GPH14

60H41B*

Cooling Capacity

AHRI Cooling Capacity (BTU/h)

40,500

40,500

46,000

46,000

57,000

57,000

Sensible BTU/h

29,600

29,600

35,400

35,400

40,500

40,500

SEER / EER

14.0 / 12.0

14.0 / 12.0

14.0 / 12.0

14.0 / 12.0

14.0 / 12

14.0 / 12

Decibels

78

78

80

80

80

80

AHRI Numbers

4385135

5677877

4385136

5677878

4385137

TBD

Heating Capacity
BTU/h (47°F)

37,600

37,600

44,000

44,000

54,500

54,500

C.O.P. (47°F)

3.8

3.8

3.8

3.8

3.6

3.6

BTU/h (17°F)

21,600

21,600

26,000

26,000

33,800

33,800

C.O.P. (17°F)

2.4

2.4

2.4

2.4

2.5

2.5

HSPF

8.0

8.0

8.0

8.0

8.0

8.0

Evaporator Motor

Type

EEM

EEM

EEM

EEM

EEM

EEM

Wheel (D x W)

10 x 8

10 x 8

10 x 8

10 x 8

11 x 8

11 x 8

Cooling CFM

1,300

1,300

1,600

1,600

1,700

1,700

Fan-Only CFM

1,200

1,200

1,400

1,400

1,600

1,600

RLA

2.9

2.9

2.9

2.9

2.9

2.9

No. of Speeds

5

5

5

5

5

5

Horsepower - RPM

½ - 1,050

½ - 1,050

¾ - 1,050

¾ - 1,050

¾ - 1,050

¾ - 1,050

Evaporator Coil
Face Area (ft

2

)

6.2

6.2

6.2

6.2

7.0

7.0

Rows Deep/ Fins per Inch

4/ 14

4/ 14

4/ 14

4/ 14

4/ 14

4/ 14

Indoor Metering Device Size

0.072

0.074

0.076

0.076

0.088

0.088

Filter Size (ft

2

)

(2) 20x20x1

(2) 20x20x1

(2) 20x20x1

(2) 20x20x1

(2) 20x25x1

(2) 20x25x1

Drain Size (NPT)

¾"

¾"

¾"

¾"

¾"

¾"

Refrigerant Charge (oz.)

150

140

190

190

200

200

Condenser Fan / Coil
Horsepower - RPM

¼ - 1075

¼ - 1075

¼ - 1075

¼ - 1075

¼ - 1075

¼ - 1075

RLA/LRA

1.4 / 2.9

1.4 / 2.9

1.4 / 2.9

1.4 / 2.9

1.4 / 2.9

1.4 / 2.9

Fan Diameter / # Fan Blades

22 / 4

22 / 4

22 / 4

22 / 4

22 / 4

22 / 4

Face Area (ft

2

)

17

17

19.1

19.1

19.1

19.1

Outdoor Metering Device Size

0.065

0.065

0.065

0.062

0.071

0.071

Rows Deep/ Fins per Inch

1 / 24

1 / 24

2 / 16

2 / 16

2 / 16

2 / 16

Compressor
Quantity / Type

1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single

Compressor RLA/LRA

17.9 / 112

17.9 / 112

19.9 / 109

19.9 / 109

26.4 / 134

26.4 / 134

Electrical Data
Voltage/Phase/ Frequency

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

Indoor Blower FLA

2.9

2.9

2.9

2.9

2.9

2.9

Outdoor Fan RLA

1.4

1.4

1.4

1.4

1.4

1.4

Total Unit Amps

22.2

22.2

24.2

24.2

30.7

30.7

Min. Circuit Ampacity¹

26.6

26.6

29.2

29.2

40.2

40.2

Min. Overcurrent Protection (amps)²

40

40

45

45

60

60

Operating & Ship Weights (lbs)

375 / 385

375 / 385

405 / 415

405 / 415

405 / 415

405 / 415

¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Note: Always check the S&R plate for electrical data on the unit being installed.