Servicing instructions, Replacing parts, Short spares list – Stovax Huntingdon 30 User Manual

Page 21: Control upgarde 11. changing between gas types

Advertising
background image

NG

LPG

COMPONENT

G20

G31

20mb

37mb

MAIN INJECTOR

IN0001

IN0054

AERATION PLATE

ME4066

ME4954

PILOT INJECTOR

PI0036

PI0037

BURNER ASSEMBLY

B0214

PB0214

THERMOCOUPLE

PI0010

MAGNETIC UNIT

GC0092

ELECTRODE

PI0053

GAS VALVE

GC0088K**

IGNITION LEAD

GC0090

FRONT COAL

CE0122

FLAME BAFFLE

CE0118

REAR PANEL

GC0135

COAL SET

GC0127

TTB SENSOR

EL0001

SENSOR LEAD

EL0064

INTERRUPTER

GC0029

STANDARD UPGRADE KIT

8455

THERMO UPGRADE KIT

8456

** Note :- The control valve is factory preset for correct gas type and

model.

13. SHORT SPARES LIST

21

SERVICING INSTRUCTIONS

REPLACING PARTS

• Reassemble in reverse order with the correct aeration

plate.

In order to change between gas types, it will be necessary

to change the following items.
• Pilot Injector
• Control Valve**
• Main Injector
• Aeration Plate
• Data badge
The relevant parts can be ordered from Gazco, always

quote the appliance type and serial number when ordering

spare parts.

** NOTE: THE CONTROL VALVE IS FACTORY PRESET

FOR CORRECT GAS TYPE AND MODEL, A NEW UNIT

WILL NEED TO BE ORDERED WHEN CHANGING

BETWEEN GAS TYPES.

See Installation Instructions, Section 1.

12. CONTROL UPGARDE

11. CHANGING BETWEEN GAS TYPES

AR1441