User instructions, Replacing the door – Stovax Huntingdon 30 User Manual

Page 7

Advertising
background image

7

7.1 Ensure the rope seal fitted to the rear of the glass frame is

intact.
• Use a ceramic glass product generally sold for cleaning

ceramic hobs to clean the glass front

• Refit glass frame and tighten screws evenly, Diagram 12

With the top still supported or removed:
• Refit front by locating in grooves and lowering into

place, Diagram 13

• Now replace top, Diagram 14

8.1

The stove is fitted with the Gazco Flue Sure System, which

will act to cut off the gas supply to the burners in the event

of incorrect operation of the flue. If the system acts to cut

off the gas supply, this indicates that there is insufficient flue

pull. If this occurs a minimum of 10 minutes should be

allowed before trying to relight. Continued operation of this

safety device means there may be a serious problem with

the flue system. A qualified gas engineer should inspect this.

Do not use the stove until an engineer says it is safe to

do so.

9.1

This is a safety feature incorporated in all GAZCO fires,

which automatically switches off the gas supply if the pilot

light goes out and fails to heat the thermocouple.

10.1 The surface coating on your GAZCO stove will ‘burn off’

during the first 24 hours of operation on high, producing a

harmless and temporary odour. If the odour persists ask

your retail for advice.

11.1 A qualified gas engineer must service the stove every 12

months. In all correspondence, always quote the appliance

type and the serial number that may be found on the data

badge on the appliance.

12.1 Any purpose provided ventilation should be checked

periodically to ensure that it is free from obstruction.

13.1 To assist in any future correspondence, your installer should

have completed this commissioning sheet, this records the

essential installation details of this appliance. In all

correspondence always quote the model No. and serial No.

14.1 Parts of this appliance become hot during normal use. It is

therefore recommended that a suitable fire guard be used

for protection of young children and the infirm. Indeed, all

parts of the appliance should be treated as a 'working

surface' except for the control touch pad area and access

panel.

14. HOT SURFACES

13. INSTALLATION DETAILS

12. VENTILATION

11. SERVICING

10. 'RUNNING IN'

9. THE FLAME FAILURE DEVICE

8. GAZCO FLUE SURE SYSTEM

14

AR1907

13

AR1908

12

AR1909

7. REPLACING THE DOOR

AR0364

11

USER INSTRUCTIONS

Advertising