1. FlUe

2.1 Additional ventilation is required to comply with the

requirements of the Building Regulations. This must be

provided using a permanently open air vent, of the size

listed, which is positioned so that it is not liable to be

blocked both inside and outside the building.

2.2 Extractor fans or cooker hoods must not be placed in the

same room or space as this can cause the appliance to emit

fumes into the room.

2.3 If any of these checks reveal problems do not proceed

with the fitting of the appliance until they have been

rectified.

2. AddITIoNAl VeNTIlATIoN

Additional Ventilation

Model
Stockton 3 - 7118
Stockton 4 - 7101/7102
Stockton 5 - 7119/7160/7161/7127/Stockton 5ML - 7130
Stockton 6 - 7100/7162/Stockton 6HL - 7117
Stockton 7 - 7120/7163
Stockton 8 - 7103/7104/7105/7113/7113LC/7113HC/7114/7128
Stockton 11 - 7106/7106LC/7106HC/7116/7116LC/7116HC

Stockton

11

Stockton

8

SL

Stockton

8

Stockton

7

Stockton

6/6HL

Stockton

5/5ML

Stockton

4

Stockton

3

mm

2

cm

2

in

2

0

0

0

0

0

0

0

0

0

0.85

5.5

550

1.70

11

1100

2.56

16.5

1650

2.56

16.5

1650

5.12

33

3300

Stockton

4

Stockton

5/5ML

Stockton

6/6HL

Stockton

7

Stockton

8

Stockton

8

SL

Stockton

11

Without Liner System

Round (diameter)

mm

mm

inch

mm

inch

inch

m

feet

150

‡150

6

135

5

1

/

2

‡6

150

‡150

6

135

5

1

/

2

‡6

4

13

4

13

4

13

4

13

4

13

4

13

4

13

4

13

150

150

6

135

5

1

/

2

6

150

150

6

135

5

1

/

2

6

150

150

6

135

5

1

/

2

6

150

150

6

135

5

1

/

2

6

180

180

7

165

6

1

/

2

7

150

150

6

135

5

1

/

2

6

Without Liner System (square)

Minimum Dimension

With Liner or Factory made System

(diameter)

installed in accordance with manufacturers instructions

Flue/Chimney

Size

Flue/Chimney

minimum height*

Model
Stockton 3 - 7118
Stockton 4 - 7101/7102
Stockton 5 - 7119/7160/7161/7127/Stockton 5ML - 7130
Stockton 6 - 7100/7162/Stockton 6HL - 7117
Stockton 7 - 7120/7163
Stockton 8 - 7103/7104/7105/7113/7113LC/7113HC/7114/7128
Stockton 11 - 7106/7106LC/7106HC/7116/7116LC/7116HC

Stockton

3

Advertising