Technical Data

Total connected load: 4 400 W
AC 208/220-240 V / 60 Hz

Important notes on installation

This appliance can be combined with all Gaggenau
Vario 400 Series appliances.

This appliance may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional safety measures.
The built-in furniture and worktop where the
appliance is installed must be heat resistant up to
temperatures of 200° F/90° C.

The appliance must only be connected by an
authorised specialist, paying attention to the
relevant regulations of the power supply companies
and the regional construction regulations.

Pay attention to the data on the rating plate. The
appliance must be properly grounded.

When connecting electrical appliances in the
proximity of cooking surfaces, make sure that
connecting cables do not come into contact with hot
cooking surfaces.

The installation technician is responsible for the
correct functioning of the appliance at the place of
installation. He must instruct the user on how to
disconnect the appliance from electricity in an
emergency.

After unpacking, check the appliance for any
transportation damage and report this immediately
to the transportation company.

There must be a gap of at least 20 mm (

13

/

16

´ ´ ) at the

side between the appliance and any walls or
furnishings.

If all poles of the appliances cannot be isolated
from the mains by removing an accessible plug, an
isolating device with a contact gap of at least 3 mm
must be installed (e.g. domestic fuse).

No warranty claims can be lodged for any
damage resulting from failure to observe these
instructions. Pay attention to the “Important