To Replace or Adjust Door Latch Mechanism

1. Open oven doors.
2. Remove 2 pan head Phillips screws.
3. Lift door latch mechanism

up and out of door

assembly.

4. To adjust latch mechanism

, loosen lock nut

& and

adjust by tightening or loosening adjustment nut.

To Replace Convection Oven Motor Assembly

(Drawing Below)

1. Open doors and remove all oven racks.

2. Remove 4 #10 sheet metal screws (that secure air baffle)

and remove air baffle.

3. Remove six hex nut 1/4-20x7/16" (2A) and lock washers

(4A) from motor mounting studs.

4. Place a piece of cardboard on oven floor to protect from

scratching or chipping.

5. Pull entire motor assembly (1A) away from rear oven wall

into oven cavity and place on cardboard.

6. Disconnect wiring, be sure to note wire locations.

7. To reinstall reverse above procedure.


















Convection Oven Motor

1

2

3

4

5

6

FILE NAME

JIT00024

4A

2A

1A