Global Machinery Company MOC6L User Manual

Page 10

Advertising
background image

10

To start the air compressor

1. Check the rating label on the compressor

indicates 230V-240V.

2. Make sure that the selected location for the compressor

is clean, dry, well ventilated and without any obstruction.

3. Conduct a visual check to the make sure that compressor

is not damaged and is fully in tack.

4. Make sure that he drain cock (13) is installed and

screwed into the closed position.

5. Connect the air hose to the quick coupler located on the

air compressor, by pushing back the outer sleeve of the

quick coupler (Fig. A) and inserting the end of the hose.

Release the outer sleeve and make sure the hose stays

in place (Fig. B).

6. Install the desired air accessory into the quick coupler at

the end of air hose by pulling back on the outer sleeve

of the quick coupler and inserting the accessory into it.

Release the outer sleeve and make sure the accessory

and hose are securely connected. For instructions on

how to assemble the accessories refer to pages 11 and 12.

7. Plug in the mains cable of

the compressor to a standard

240V household power point

and turn it on.

8. To start the compressor, press

the yellow “On/Off” (1) switch

to the “on” setting located on

top of the compressor (Fig. C).

WARNING.

Be aware that pressurised air will be discharged

from the outlet and care should be taken that this discharge

is not directed towards you the operator, or other persons

within the area.
9. To stop the compressor, push the yellow “On/Off” (1)

switch to the “off” setting.

Operating the air compressor

1. The pressure in the tank is controlled by the action of

a pressure switch. When the set maximum pressure is

reached the pressure switch activates and the motor

is switched off. The pressure then decreases as the

air is used by the connected tool until the set minimum

pressure is reached after which the pressure switch

causes the motor to switch on again. The operator of

the compressor should be well aware that during use of

the compressor the motor will start and stop under the

influence of the rising or falling pressure in the tank. The

motor will start without any warning.

2. The maximum and minimum pressures are factory set

and the operator should not try to change them.

3. All accessories are connected

to the regulated outlet valve (8).

4. The pressure of the regulated

outlet, as shown on the

regulated outlet pressure

gauge (12), can be changed

by turning the regulating

knob (9) (Fig. D).

Note.

To obtain the correct output reading on the regulated

output gauge, the air must be flowing through the regulated

outlet valve and the selected air tool/accessory.
The air pressure regulating knob should be adjusted

and the gauge must be read. Only read the gauge when

the regulated outlet valve has the air hose connected

with the selected air tool/accessory attached and drawing

air/discharging.
Do not start the application until you have set the regulated

outlet pressure accordingly for the selected tool/accessory.

A

B

C

D

Advertising