Global Machinery Company MOC6L User Manual

Page 16

Advertising
background image

16

Troubleshooting continued

Problem

Possible cause

Suggested remedy

Insufficient pressure or decreased

outlet capacity continued

Air fittings leaking.

Check all air fittings. Make sure that
they are tight and not leaking at the
joins. If a quick release fitting is leaking,
disconnect it and reconnect it. If it
continues to leak replace the defective
fitting(s). If a male or female fitting
is leaking around the thread tighten
using a spanner. If the fitting is already
tight and can’t be tightened anymore
unscrew the connection, remove the
Teflon tape and look at the condition
of the fitting(s). If the a fitting(s) is
damaged replace and reassemble
using Teflon tape on threaded fittings.
If the fitting looks OK or reapply Teflon
tape and re assemble.

Maintenance

1. After each day of operation,

use the drain cock (13) under

the tank to drain out any

condensation (Fig. O).

2. After each day of operation

check daily the operation of

the safety valve (10). This

check should be performed

when the tank contains close

to max pressure.

To check the valve, pressurise the tank, and pull the

ring OUTWARDS on the safety valve.
Air should discharge from the valve.
Release the ring of the safety valve. When the ring is

released the air discharge must stop.

WARNINGS.

Safety glasses must be worn when performing this test.
Do not have your face close to the safety valve when

performing this test as air will discharge from the valve at a

high force.
If the safety valve does not operate correctly in any way as

described above, turn off the compressor immediately and

have the compressor and safety valve checked and tested

at an authorised Service centre.
DO NOT CONTINUE TO USE THE COMPRESSOR IN

ANY WAY IF THE SAFETY VALVE DOES NOT WORK

AS ABOVE.

General inspection

1. Regularly check that all the fixing screws are tight.
2. The supply cord of the tool should be checked frequently

for damage. If damaged, have the cordset replaced by an

authorised service facility to avoid a hazard.

O