Global Machinery Company MOC6L User Manual

Page 12

Advertising
background image

12

3. Connect the completed assembly to the air line by

pulling back the outer sleeve of the quick coupler at the

end of the air hose and insert the quick change blower

assembly. Once inserted, release the outer sleeve of

the coupling and make sure the accessory and hose are

securely connected.

For instructions on how to assemble the accessories to

the outlet side of the quick release blow gun refer to

page 12 of this manual.

4. To discharge the air from

the gun, squeeze the trigger

(Fig. J). The further the

trigger is squeezed, the

greater the discharge.

5. To stop the air discharging,

release the trigger.

Note.

When connecting accessories to the outlet of the quick

change blow gun (15) always disconnect it from the hose

first. This will allow you more freedom as well as provide

for a more easier and safer attachment/detachment of

accessories. The dust blow gun is to be used in conjunction

with either the tapered inflation fitting (17) or the inflation

needle (19).

IMPORTANT.

Take extreme care when using the blow gun

air tool. The discharge air velocity is VERY high.

Never point the air gun at anyone.

Think when you are using the gun. Never allow

debris to be blown in the direction of another person,

or other objects.

Use safety glasses, a face or dust mask and appropriate

clothing for the task being undertaken.

Never apply the outlet of the air gun against a

person’s body.

Never look down the air outlet hole of the gun.

Connecting the inflation needle

to the quick change blow gun

In order to use the inflation needle you are required to

attach the blow gun adaptor (16) to the blow gun (15).

Proceed to screw in the inflation needle (19) to the safety

nozzle (Fig. K&L).

IMPORTANT.

Take extreme care when using the

inflation needle.

Never point the needle at anyone.

Use safety glasses, a face or dust mask and appropriate

clothing for the task being undertaken.

Never apply the outlet of the needle against a

person’s body.

Never look down the air outlet hole of the inflation needle

Always apply lubricant to the needle before inserting

and inflating.

When inserting the needle, insert the open end of the

needle into the valve in a slow and safe manner.

Connecting the tapered inflation fitting to the

quick change blow gun

In order to use the tapered

inflation fitting you are required to

attach the blow gun adapter (16)

to the blow gun (15). Proceed

to screw in the tapered inflation

fitting (17) to the blow gun

adaptor (16) (Fig. M).

J

L

K

M

Advertising