Dip switch configuration – Gefen EXTRA LONG RANGE EXTENDER GTB-HDKVM-ELR User Manual

Page 14

Advertising
background image

11

DIP SWITCH CONFIGURATION

Receiver Unit

DIP Switch 2 - Hot Plug Detect (Default = OFF)*

• ON - HPD Pass-Through

HPD follows upstream HPD towards the source. The HPD signal will refl ect
the connection status between the display device and the source device. If
the source or monitor is temporarily disconnected then reconnected, there
will be a delay of 20 - 30 seconds before the content is restored to the
monitor.

• OFF - HPD Always High

The HPD signal remains high regardless of the downstream HPD state.
If the source or monitor does not properly handle HPD (no picture after
connecting / reconnecting source or display), set this DIP switch to the OFF
position.

DIP Switch 3 - Supports DVI Connections (Default = OFF)*

• ON - Disable HDCP

If a DVI connection is used, set DIP 3 to the ON position. DVI is supported
by disabling HDCP pass-through.

• OFF - Enable HDCP

If an HDMI device is connected, set DIP 3 in the OFF position.

DIP Switch 4 - Not Supported

Reserved for future use

*DIP switch is only operational when using Local EDID (DIP 1 = OFF).