Performance data sheet, Operating specifications, Special notices – GE 200D8074P036 User Manual

Page 31

Advertising
background image

31

Manufactured for: General Electric Company, Louisville, KY 40225

Performance Data Sheet

SmartWater Filtration System

MSWF Cartridge

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration
of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

Parameter

USEPA

Influent

Effluent

% Reduction

Min. Required

MCL

Challenge Concentration

Average

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L + 10%

0.06 mg/L

0.10 mg/L

97%

95.1%

≥ 50%

Particulate**

at least 10,000 particles/mL

408,333

670,000

95.5%

89.4%

≥ 85%

Standard No. 53: Health Effects

Max. Permissible

Product Water

USEPA

Influent

Effluent

% Reduction

Concentration

Parameter

MCL

Challenge Concentration

Average

Maximum

Average

Minimum

mg/L

Turbidity

1 NTU***

11 + 1 NTU***

0.38 NTU

0.5 NTU

96.5%

95.4%

0.5 NTU

Cysts

99.95% Reduction

Minimum 50,000 L

< 1 #/L

4 #/L

> 99.99%

> 99.99%

99.95%

Lead at pH 6.5

0.010 mg/L

0.15 mg/L + 10%

< 1 ppb

< 1 ppb

99.3%

99.3%

0.010 mg/L

Lead at pH 8.5

0.010 mg/L

0.15 mg/L + 10%

3.1 ppb

9.0 ppb

98.0%

95.5%

0.010 mg/L

Mercury at pH 6.5

0.002 mg/L

0.006 mg/L + 10%

0.34 ppb

0.7 ppb

94.1%

89.6%

0.002 mg/L

Mercury at pH 8.5

0.002 mg/L

0.006 mg/L + 10%

0.66 ppb

1.5 ppb

88.4%

73.7%

0.002 mg/L

Lindane

0.0002 mg/L

0.002 mg/L + 10%

< 0.02 ppb

< 0.02 ppb

> 99.0%

> 99.0%

0.0002 mg/L

Atrazine

0.003 mg/L

0.009 mg/L + 10%

< 0.5 ppb

< 0.5 ppb

> 93.9%

> 94.3%

0.003 mg/L

2,4-D

0.070 mg/L

0.210 mg/L + 10%

7.7 ppb

35 ppb

96.0%

82.0%

0.070 mg/L

Toxaphene

0.003 mg/L

0.015 mg/L + 10%

< 1 ppb

< 1 ppb

> 92.9%

> 92.9%

0.003 mg/L

Benzene

0.005 mg/L

0.015 mg/L + 10%

< 0.5 ppb

< 0.5 ppb

> 96.8%

> 97.0%

0.005 mg/L

Carbofuran

0.040 mg/L

0.080 mg/L + 10%

< 1 ppb

< 1 ppb

> 98.7%

> 98.7%

0.04 mg/L

P- Dichlorobenzene

0.075 mg/L

0.225 mg/L + 10%

< 0.5 ppb

< 0.5 ppb

> 99.7%

> 99.8%

0.075 mg/L

Asbestos

99% Reduction

10

7

to 10

8

fibers/L; fibers > 10µm in length

< 0.17 MF/L

< 0.17 MF/L

> 99%

> 99%

99%

* Tested using pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 2.5°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity Units

Operating Specifications

Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light;
up to one year for models with a replacement filter indicator light
Pressure requirement: 20–120 psi (1.4–8.2 bar), non-shock
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.89 gpm (3.4 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 5 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be
installed and operated in accordance with manufacturer’s recommended procedures and guidelines.

NSF

®

System Tested and Certified by NSF International against NSF/ANSI Standard 42 & 53 for the reduction of:

Standard No. 42: Aesthetic Effects
Chemical Unit

Taste and Odor Reduction
Chlorine Reduction

Mechanical Filtration Unit

Nominal Particulate Reduction, Class I

Standard No. 53: Health Effects
Chemical Unit

Lead, Mercury and Atrazine Reduction
Lindane, Toxaphene and 2,4-D Reduction
Benzene, Carbofuran and
P-Dichlorobenzene Reduction

Mechanical Filtration Unit

Turbidity Reduction, Cyst Reduction,
Asbestos Reduction

Advertising