Greenheck Fan Steel Airfoil Blades FSD-331 User Manual

Model fsd-331 combination fire smoke dampers, Application, Ratings

Advertising
background image

APPLICATION

Model FSD-331 is a high performance combination fire smoke damper

with extremely low leakage. High strength airfoil blades ensure the

lowest resistance to airflow in HVAC systems with velocities to 2000

fpm (10.2 m/s) and pressures to 4 in. wg (1 kPa). Model FSD-331 may

be installed vertically (with blades running horizontal) and is rated for

airflow and leakage in either direction.

RATINgs

UL 555 Fire Resistance Rating

Fire Rating:

3

hours

Dynamic Closure Rating: Actual ratings are size dependent

Max. Velocity:

up to 2000 fpm (10.2 m/s)

Max. Pressure:

4 in. wg (1 kPa)

UL555S Leakage Rating

Leakage Class:

I

Operational Rating:

Actual ratings are size dependent

Max. Velocity:

up to 3000 fpm (15.2m/s)

Max. Pressure:

4 in. wg (1 kPa)

Maximum Temperature: 350°F (177°C)- depending upon the

actuator

sTANdARd CONsTRuCTION

Frame:

5 in. x 1 in. (127mm x 25 mm)

galvanized steel hat channel with

reinforced corners. A low profile head

and sill are used on sizes less than

17 in. (432mm)

Blades:

Double skin airfoil shape of

galvanized steel with full length

structural reinforcement. 14 ga.

(2 mm) equivalent thickness.

Seals:

Extruded silicone rubber blade seals

Flexible stainless steel jamb seals.

Linkage:

Concealed in jamb.

Closure Device:

RRL 165°F (74°C)

Axles:

1

2

in. (13mm) dia. plated steel.

Bearings:

Bronze sleeve type.

sIze LImITATIONs:

minimum size:

8 in. W x 6 in. H

(203 mm W x 152mm H)

maximum size (Vertical Only):

Single Section:

32 in. W x 36 in.H

(813mm W x 914mm H) or

30 in. W x 48 in. H

(762mm x 1219mm)

Multiple Section:

120 in. W x 96 in. H

(3048mm W x 2438mm H)

OPTIONAL FeATuRes:

• RRL/OCI (Open closed indication switches)

• 165ºF (74°C), 212ºF (100°C), 250ºF (121°C), 350ºF (177°C) RRL's

available

• TOR (remote override closure allows damper to perform smoke

management functions during a fire emergency.)

• Electric or pneumatic actuators to accomplish smoke management

and system functions.

• POC retaining angles

• Smoke detectors

• Momentary Switch

• Transitions (R, C, O)

• PRV (pneumatic relief valve)

• Security Bars

• Sealed transitions and sleeves

model Fsd-331

Combination Fire smoke dampers

Steel Airfoil Blades

UL 555S Leakage Class I

UL555 3 Hour Fire Resistance Rating

*W&H dimensions furnished approximately

1

/

4

in. ( 6 mm) undersize.

(Add sleeve thickness for overall sleeved damper dimension)
Right hand drive is shown. Left hand drive is available upon request.

H*

W*

LH

RH

Model FSD-331 meets the requirements for fire

dampers, smoke dampers and combination fire

smoke dampers established by:
National Fire Protection Association

NFPA Standards 80, 90A, 92A, 92B, 101 & 105
IBC International Building Codes
ICBO uniform Building Codes
CsFm California state Fire marshal
Fire Damper Listing (#3225-0981:103)
Leakage (Smoke) Damper Listing (#3230-0981:104)
New York City (MEA listing #260-91-M)

“uL CLAssIFIed (see complete marking on

product)”

“uL CLAssIFIed to Canadian safety standards

(see complete marking on product)”

Standard 555 & 555S (Listing #R13317)

Installation instructions available at www.greenheck.com

R

Greenheck Fan Corporation certifies that the

model FSD-331 shown herein is licensed to

bear the AMCA Seal. The ratings shown are

based on tests and procedures performed

in accordance with AMCA Publication 511

and comply with the requirements of the

AMCA Certified Ratings Programs. The

AMCA Certified Ratings Seal applies to air

performance ratings only.

Advertising