Operation – Gardena ErgoJet EJ3000 User Manual

Page 5

Advertising
background image

Convertingunitfromvacuum

usetobloweruse:

1.Stopunitandunplugtheextensioncord.
2.Removetheelbowtubeandcollectionbag.
3.Removethevacuumtubesbyreleasingthelatchonthevacuum

inletcoverandrotatingthecoveruntilthetubesarereleased

fromthelatchesoftheretainingposts.

4.Closetheinletcoverandmakesureitislatchedclosed.
5.Re-installtheblowertube.RefertoFITTINGTHEBLOWER

TUBEforinstructionsonhowtoattachthisitem.

NOTE:Asafetyswitchwillpreventtheunitfromstartingiftheinlet

coverisnotlatchedclosed.

4. Operation

WARNING:

Do not use the unit without the tubes or collection bag properly

attached to avoid flying debris and/or impeller contact which can cause serious

injury. Alwayswearglovesanduseeyeprotectiontopreventrocksordebrisfrom

beingblownorricochetingintotheeyesandfacewhichcanresultinblindnessor

seriousinjury.

Cables:

Useonly1.00mm

2

sizecableupto40metreslengthmaximum.

Maximum rating:

1.00mm

2

sizecable

3000W
Mainscablesandextensionsareavailablefromyourlocal

approvedservicecentre.Onlyuseextensioncablesspecifically

designedforoutdooruse.

Connectingtheunit–

cablelock/extensioncables:

Looptheextensioncable

i

andinsertitintothecablelock

o

.

Thispreventsunintentionalseparationoftheelectricalconnection.

Thenconnectittothemainscable.

i

o

Startingtheblower:

p

a

Switching the blower on:

MovetheON/OFFswitch

p

totheON(I)positiontoturnonthe

unit.
NOTE:Themotorspeedcanbeincreasedordecreasedbyusing

thevariablespeedcontrol

a

.

CAUTION:Toavoidcausingdamagetotheunit,onlyusethe

variablespeedcontrolinblowmode.DONOTattempttousethe

variablespeedcontrolinvacuummode.Lowerspeedsduring

vacuumusecouldallowdebristobuildup,stallthemotorand

causeunitfailure.

Switching the blower off:

Tostoptheunit,movetheON/OFFswitch

p

tothe

OFF(0)position.

Workingpositions:

Blow mode
Useyourunitasablowerforsweepingdebrisorgrassclippings

fromdriveways,sidewalks,patios,etc.Also,forblowinggrass

clippings,straw,orleavesintopiles,orremovingdebrisfrom

corners,aroundjoints,orbetweenbricks.
Usethevariablespeedcontroltoincreaseordecreasethemotor

speedduringbloweruse.Directairflowbydirectingtheblower

tubedownortooneside.
Alwaysworkawayfromsolidobjectssuchaswalks,largestones,

vehicles,andfences.
Cleancornersbystartingincornersandmovingoutward.Thiswill

helppreventanaccumulationofdebriswhichcouldflyintoyour

face.Becarefulwhenworkingnearplants.Theforceoftheair

coulddamagetenderplants.

Vacuum mode
Useyourunitasavacuumtopickupdrymaterialsuchasleaves,

grass,smalltwigs,andbitsofpaper.
Forbestresultsduringvacuumuse,operateyourunitathigh

speed.
Moveslowlybackandforthoverthematerialasyouvacuum.

Avoidforcingtheunitintoapileofdebrisasthiscanclogtheunit.
Keepthevacuumtubeaboutaninchabovethegroundforbest

results.

WARNING:

If the unit becomes clogged, stop the unit and unplug the

extension cord. Wait until the impeller has completely stopped turning,

then remove the vacuum tubes. Carefully reach into the vacuum opening

and clear out the clogged debris.

Thiswillreducepossiblepersonalinjuryfromtheimpeller.

22

GB

23

GB

Advertising