27

308–530

4. With crankcase side of manifold down remove

hi–pressure seals using a reverse pliers.

5. Invert manifold so crankcase side is up and with

reverse pliers remove low pressure seals.

Reassembly:
1. Examine low pressure seal for seal wear or spring

failure and replace if necessary. With crankcase side

of inlet manifold up, lubricate seal and press into

valve chamber with garter spring down. Carefully

square seal into position.

2. Examine hi–pressure seal for wear and replace if

necessary. Invert inlet manifold with crankcase side

down, lubricate seal and press into chamber with

v–side up. Carefully square into position.

3. Rotate shaft so the two (2) outside plungers are

extended and lined–up.

4. Lubricate plungers and discharge valve adapter

o–rings.

5. Carefully line–up and

join the inlet and discharge

manifolds by pressing the protruding discharge valve

adapters into the inlet manifold seal chambers.

6. Replace all four (4) discharge manifold socket head

bolts and washers and hand tighten.

7. Then carefully slip manifold assembly onto plungers

and tap with soft mallet until flush with crankcase.

8. Replace the two (2) inlet manifold socket head bolts

and washers and hand tighten. Then torque per

chart.

9. Then torque the four (4) discharge manifold socket

head bolts per chart.

Servicing the Plungers

Disassembly:
1. Remove discharge and inlet manifold as described.

2. Using a wrench loosen plunger retainers

approximately three (3) to four (4) turns.

3. Grasp ceramic plunger and push towards crankcase

until plunger retainers with stud pop out.

4. Remove plunger retainer and copper gasket.

5. Remove ceramic plunger from plunger rod.

6. Remove barrier slinger from plunger rod.

Reassembly:
1. Replace barrier slinger if necessary and

position

onto plunger rod.

2. Carefully examine ceramic plunger for scoring or

cracks and replace if worn. Slip onto rod.

NOTE: Ceramic plunger can only be installed one

direction (front to back). Do not force onto rod.

3. Examine o–ring and back–up ring on plunger

retainer and replace if worn or cut. Lubricate o–ring

for ease of installation and to avoid damage to

o–rings.

NOTE: First install NEW copper gaskets on plunger

retainers, then back–up rings and o–rings.

4. Install short threaded end of stud into plunger

retainer.

5. Thread plunger retainer and stud assembly into

plunger rod and torque per chart. (Long threaded end

of stud into plunger rod.)

NOTE: Exercise caution not to over torque the plunger

retainer.

6. Rotate shaft so the two (2) outside plungers are

extended and lined–up. Then lubricate plungers.

7. Replace all four (4) discharge manifold socket head

bolts and washers and hand tighten.

8. Then carefully slip manifold assembly onto plungers

and tap with soft mallet until flush with crankcase.

9. Replace the two (2) inlet manifold socket head bolts

and washers and hand tighten. Then torque per

chart.

10. Then torque the four (4) discharge manifold socket

head bolts per chart.

Servicing Crankcase Section

1. While inlet manifold, plungers and seal retainers are

removed, examine crankcase seals for wear.

2. Check oil level and for evidence of water in oil.

3. Rotate crankshaft by hand to feel for smooth bearing

movement.

4. Examine crankshaft oil seal externally for drying,

cracking or leaking.

5. Consult factory or your local distributor if crankcase

service is required.

Torque Chart

Pump Part

Thread Tool Size Torque

Plunger Retainer M5

11 mm hex 80 in. lbs.

Inlet Manifold

Bolts

M10

8 mm allen 132 in. lbs.

Discharge

Manifold Bolts

M10

8 mm allen 180 in. lbs.