Graco Inc. Hydra-Clean 308-530 User Manual

Page 8

Advertising
background image

8

308–530

SHUTDOWN, FLUSHING

AND STORAGE

WARNING

Pressure Relief Procedure
To reduce the risk of serious bodily injury, including

fluid injection and splashing in the eyes, or on the

skin, always follow this procedure whenever you

stop spraying for more than 10 minutes, when

shutting down, and before checking or repairing

any part of the system.

1. Engage the trigger safety latch.

2. Turn the sprayer off.

3. Remove the ignition cable from the spark plug.

4. Shut off the water supply.

5. Disengage the trigger safety latch and trigger

the gun to relieve pressure, and then engage

the trigger safety latch again.

6. Before long–term (overnight) storage or

transporting of unit, disconnect the water

supply, and turn off the fuel supply valve.

1. If the pressure washer will be exposed to freezing

temperatures, drain all water out of the pump. If it

must be stored in freezing temperatures, flush the

unit with a 50%

anti–freeze solution. Relieve

pressure. Flush the pressure washer before using it

again to remove the anti–freeze.

NOTE: An anti–freeze flush kit, P/N 802–327, is

available to make flushing easier.

CAUTION

If water does freeze in the pressure washer, thaw

it in a warm room before trying to start it.

DO NOT

pour hot water on or into the pump; it may crack

the ceramic plungers!

2. After each use, wipe all surfaces of the pressure

washer with a clean, damp cloth.

3. Perform the appropriate maintenance. See

maintenance chart.

MAINTENANCE

Observing regular maintenance intervals helps ensure

that you get maximum performance and life from the

pressure washer.

There is a break–in period for the engine, pump and gear

reducer (if used). After changing the oil in these

components following their respective break–in periods,

the interval between required changes is longer.

If the unit is operating in dusty conditions, these

maintenance checks should be made more often.

WARNING

To reduce the risk of serious bodily injury

,

including fluid injection, splashing in the eyes or

on the skin or injury from moving parts, always

follow the

Pressure Relief Procedure Warning

before proceeding.

Interval
Daily

After first 5

hours of

operation
Each 25 hours

of operation

After first 50

hours of

operation

Each 100

hours of

operation

or 3 months

Each 500

hours of

operation

or 6 months

What to do
Clean water inlet screen and

filter. Check engine and pump oil

levels. Fill as necessary. Check

gasoline level. Fill as necessary.
Change engine break–in oil.

Drain oil when warm. Use SAE

30 or 10W–30 detergent oil.
Clean and remove air cleaner

foam. Wash with water and

detergent. Dry thoroughly. Rub

with oil and squeeze to distribute

oil.
Change pump break–in oil. Use

SAE 20 or 30 non–detergent oil

or genuine Cat

R

pump oil.

Change gear reducer oil. Use

SAE 90 gear oil on 2040 and

2540. The 1535 uses the oil in

pump crankcase.
Clean or replace paper air

cleaner cartridge. Tap gently to

remove dirt. Change engine oil.

Use SAE 30 or 10W–30

detergent oil.
Change pump oil. Use SAE 20 or

30 non–detergent oil or genuine

Cat

R

pump oil. Change gear

reducer oil on 2040 and 2540.

Use SAE 90 gear oil. The 1535

uses the oil in pump crankcase.

Advertising