Graco Inc. Hydra-Clean 308-530 User Manual

Page 28

Advertising
background image

28

308–530

PUMP SERVICE (Models 2040 & 2540)

Servicing the Valves

1. Remove the hex valve plug.

2. Examine the o–ring under the plug for cuts or

distortion and replace if worn. Lubricate new o–ring

before installing.

3. Grasp valve retainer by tab at the top with pliers and

remove from valve chamber . Valve parts usually

separate during removal.

Note:

A special tool will be needed to remove the seat

from the manifold. A reverse pliers or a

standard vise grip and a 1/4” x 3” bolt to fit I.D. of

seat inserted under the edge of the seat, will pry

the valve seat out easily.

4. Examine all valve parts for wear and replace with

preassembled valve assembly in service kit

containing retainer, spring, valve, valve seat, o–ring,

and back–up ring.

5. Grasp new valve assembly by tab at top with pliers,

immerse in oil and push into valve chamber

. Be

certain valve assembly is square in valve chamber.

6. Apply Loctite 242 to valve plug, thread into manifold

port and torque per chart.

Note:

Corrosion Resistant models require the coil

spring installed in the Valve Plug.

Servicing the Pumping Section

Disassembly:
1. Remove the four (4) hex nuts or two (2) bolts from the

manifold (varies with model).

2. Rotate crankshaft by hand to start separation of

manifold from crankcase. Support the underside of

the manifold and tap lightly with a mallet to remove

the manifold assembly.

CAUTION

Keep manifold properly aligned with ceramic

plungers when removing to avoid damage to

either plungers or seals.

3. Remove oil pan and slide out seal retainer with wicks.

4. Using a wrench, loosen the plunger retainer. Grasp

ceramic plunger and push toward crankcase until

plunger retainer pops out.

5. Remove plunger retainer with copper gasket,

back–up Ring and o–ring.

6. Remove plunger from plunger rod.

Reassembly:
1. Carefully examine each ceramic plunger for scoring

or cracks, replace if worn and slip onto plunger rod.

Note:

Ceramic plunger can only be installed one

direction (front to back). Do not force onto rod.

2. Examine plunger retainer and stud and replace if

worn.

Note:

Thread stud into plunger retainer.

3. Examine o–ring, back–up ring and gasket on plunger

retainer and replace if worn or cut. Lubricate o–ring

for ease of installation and to avoid

damaging

o–rings.

Note:

First install gasket, then back–up ring and

o–ring.

4. Thread plunger retainer and stud assembly into

plunger rod. Exercise caution not to over torque.

5. Saturate new oil wick by soaking in oil, place in seal

retainer and slip retainer over ceramic plunger.

6. Replace oil pan.

7. Turn shaft by hand to line up plungers so end

plungers are parallel.

8. Carefully slip manifold onto plungers, keeping

manifold level, and tap with mallet to bring manifold

flush with crankcase.

9. Replace washers and nuts or bolts and torque per

chart.

Servicing the Seals and V–Packings

Disassembly:
1. Remove the manifold as described.

2. With crankcase side of manifold facing up, unscrew

the seal case from the manifold using a special key

wrench.

3. Remove o–ring from seal case.

4. Remove snap ring and low pressure seal from the

seal case. Seals are generally removed easily

without any tools.

5.

High Pressure Seal Models: The high pressure

seal is generally easily removed from the manifold

without any tools. If extremely worn a reverse pliers

may be used.

6.

V–Packing Models: The female adapter

, two

v–packings and male adapter are easily removed

from manifold without tools. If extremely worn a

reverse pliers may be used.

Advertising