Always use this startup procedure to ensure that the unit

is started safely and properly.

1. Check oil levels.

Engine: Add SAE 30 or 10W–30 weight detergent oil

as necessary.

Pump: Add SAE 20 or 30 weight non–detergent oil or

genuine Cat

R

pump oil as necessary.

Gear Reducer (2040 and 2540): Add SAE 90 gear oil

as necessary . The 1535 uses the oil in pump

crankcase.

NOTE: All units are equipped with a low–oil sensor that

shuts the engine off if the oil level falls below a

certain level. If the unit stops unexpectedly ,

check both the oil and the fuel levels. Check the

oil level each time the unit is refueled.

2. Check fuel level.

WARNING

DO NOT refuel a hot engine. Refueling a hot

engine could cause a fire. Use only fresh, clean

regular or unleaded gasoline. Close the fuel

shutoff valve during refueling.

3. Turn on the water supply.

CAUTION

Never run the unit dry. Costly damage to the pump

will result. Always be sure the water supply is

completely turned on before operating.

4. Trigger the gun until water sprays from the tip

indicating that the air is purged from the system.

5. Open the fuel shutoff valve. Be sure the spark plug

ignition cable is pushed firmly onto the spark plug. On

those units equipped with an ignition shutoff switch,

put the switch in the “on” position and put the throttle

in the “run” position.

6. Start the engine.

NOTE: For easier starting, have one person start the

pressure washer while another person triggers

the spray gun.

If the engine is cold, completely close the engine

choke. Grasp the starter rope, brace one foot on the

pressure washer chassis and pull rope rapidly and

firmly. Continue holding the rope as it returns. Pull

and return the rope until the engine starts. In cool

weather, the choke may have to be kept closed for 10

to 30 seconds before opening it to keep the engine

running. Otherwise, open the choke as soon as the

engine starts.

If the engine is warm, leave the choke open, or just

partly close it. Start the engine as described in the

preceding paragraph. When it starts, be sure to open

the choke completely.

CAUTION

On recoil start engines, never let the starter rope

return by itself. It could jam the recoil system.

7.

ALWAYS engage the gun’ s trigger safety latch

whenever you stop spraying, even for a moment, to

reduce the risk of fluid injection or splashing in the

eyes or on the skin if the gun is bumped or triggered

accidentally.

8.

ALWAYS observe the following CAUTIONS to avoid

costly damage to the pressure washer.

CAUTION

DO NOT allow the pressure washer to idle for more

than 10 minutes. Doing so may cause the

recirculating water to overheat and seriously

damage the pump. Turn off the pressure washer if it

will not be spraying or cleaning at least every 10

minutes. If heated inlet water is used, reduce this

time further.

DO NOT run the pump dry , which will quickly

damage the pump. Be sure the water supply is fully

turned on before starting the pump.

DO NOT operate the pressure washer with the inlet

water screen removed. This screen helps keep

abrasive sediment out of the pump, which could

clog or scratch the pump. Keep this screen clean.

DO NOT pump caustic materials; such materials

may corrode the pump components.

9. See the chemical injector or sandblaster kit manual

for detailed cleaning information if these accessories

are used.