13

If adjustment is necessary…

Turn off the power to the water
heater.

Remove the jacket access panel(s)
and insulation exposing the
thermostat(s).

The thermostat protective cover(s)
should not be removed.

Using a small screwdriver, set the
thermostat(s) dial pointer(s) to
the desired temperature.

Replace the insulation and jacket
access panel(s). Turn on the power
to the water heater.

R

E

S

E

T

R

E

S

E

T

TURN OFF

POWER

BEFORE

SERVICING

90

°F

150

°F

125

°F

Type 59T thermostat and
protective cover.

Time/Temperature Relationship in Scalds

Temperature

Time To Produce a Serious Burn

120°F

More than 5 minutes

125°F

1

1

/

2

to 2 minutes

130°F

About 30 seconds

135°F

About 10 seconds

140°F

Less than 5 seconds

145°F

Less than 3 seconds

150°F

About 1

1

/

2

seconds

155°F

About 1 second

Table courtesy of Shriners Burn Institute

DANGER: There is a hot

water scald potential
if the thermostat is set
too high. Households with
small children, disabled, or
elderly persons may
require a 120°F or lower
thermostat setting to
prevent contact with
HOT water.

Water Temperature Setting

The temperature of the water in the
water heater can be regulated by setting
the temperature dial of the adjustable
surface mounted thermostat(s) located
behind the jacket access panel(s).

Dual element heaters have two
thermostats.

Safety and energy conservation are
factors to be considered when selecting
the water temperature setting of the
water heater’s thermostat(s). The lower
the temperature setting, the greater the
savings in energy and operating costs.

To comply with safety regulations the
thermostat(s) are factory set at 120°F
or less where local codes require. This is
the recommended starting point.

Water temperatures above 125°F
can cause severe burns or death from
scalding. Be sure to read and follow the
warnings outlined in this manual and on
the label on the water heater. This label
is located on the water heater near the
thermostat access panel.

Mixing valves are available for reducing
point of use water temperature by mixing
hot and cold water in branch water lines.
Contact a licensed plumber or the local
plumbing authority for further
information.

The chart below may be used as a guide
in determining the proper water
temperature for your home.

Reset button

Thermostat

protective

cover

Thermostat
dial pointer

Safety Instructions

Installation Instructions

Operating Instructions

Care and Cleaning

T

roubleshooting Tips