Setting operation modes, 12 f – Graco PRECISIONSWIRL 310554V User Manual

Page 22

Advertising
background image

PrecisionSwirl Module Operation

22

310554V

Setting Operation Modes

The PrecisionSwirl module has two operating states:

Automatic mode — enables the PrecisionSwirl
orbital dispenser to be controlled by a remote signal
source, such as a robot control. Motor speed can be
controlled by a 0-10 VDC analog signal.

Manual mode — enables the PrecisionSwirl orbital
dispenser to swirl when you press the
RUN/ENABLE button on the control assembly.
Swirling continues until the STOP button is pressed.

The PrecisionSwirl orbital dispenser is in an idle state
until you press the RUN/ENABLE button on the control
assembly. The only time the PrecisionSwirl orbital dis-
penser can swirl material is when the RUN/ENABLE
button is pressed in either Automatic or Manual mode.
When the STOP button is pressed, the PrecisionSwirl
orbital dispenser becomes idle and will not swirl mate-
rial.

The procedures in this section configure the module for
manual or automatic operation.

F

IG

. 12

0/7%2

-/4/2

25.

-!).

25.

#/.42/,

!54/-!4)#

-!.5!,

-!.5!,

8030A

Material flow rate and “ON/OFF” flow are not con-
trolled by the PrecisionSwirl orbital dispenser.
These must be controlled by the other interfaces.
Contact your Graco Distributor for assistance.

Advertising