Adjusting orbital dispenser motor speed – Graco PRECISIONSWIRL 310554V User Manual

Page 24

Advertising
background image

PrecisionSwirl Module Operation

24

310554V

Adjusting Orbital Dispenser Motor Speed

Adjust the orbital dispenser motor speed in the manual or automatic control mode as described in the following para-
graphs.

Manual Mode:

Adjust motor speed by rotating the MANUAL SPEED
CONTROL knob on the control box. See F

IG

. 12.

Rotate the knob clockwise to increase speed and coun-
terclockwise to decrease speed. Use the motor speed
chart (F

IG

. 13) to find the manual control setting required

to achieve the desired motor speed.

Automatic Mode:

Use the motor speed chart (F

IG

. 13) to find the voltage

setting required to achieve the desired motor speed.
When the control signal voltage is increased, the motor
speed increases. When the control signal voltage is
decreased, the motor speed decreases.

Exceeding the maximum analog speed control volt-
age may result in damage to the motor controller.

F

IG

. 13

24

22

20

18

16

14

12

10

8

6

4

2

0

0

1

2

3

4

5

6

7

8

9

Analog speed signal from robot (Volts dc)

PrecisionSwirl Motor Speed Command

S

PEED IN R

P

M

x

1000

OR

Manual control setting

0-10 VOLT