Installation Instructions

16

CONNECTING AN ELECTRIC DRYER (cont.)

CONNECTING DRYER USING 3-WIRE
CONNECTION

1. Turn off the circuit breaker(s) (30 amp) or remove

the dryer’s circuit fuse at the electrical box.

2. Be sure the dryer cord is unplugged from the

wall receptacle.

3. Remove the power cord cover located at the

upper back.

4. Bring the power cord through the bracket.
5. Connect power cord as follows:

A. Connect the 2 hot lines to the outer screws

of the terminal block (marked L1 and L2).

B. Connect the neutral (white) line to the center

of the terminal block (marked N).

6. Be sure ground strap is connected to green

ground screw on cabinet rear. Tighten all
terminal block screws (3) completely.

7. Reinstall the cover.

WARNING –

NEVER LEAVE THE

COVER OFF OF THE TERMINAL BLOCK.

Ground strap

Bracket