Installation instructions, Warning, Caution – GE PCVH480EK User Manual

Page 19

Advertising
background image

Installation Instructions

19

WARNING

USE ONLY METAL DUCT 4

″ DIAMETER (102 mm

FOR CANADA). DO NOT USE DUCT LONGER THAN
SPECIFIED IN THE EXHAUST LENGTH TABLE.

Dryer Exhausting Information—Metal Duct Only

Ducting Materials: For best performance, this dryer
should be vented with 4

″ diameter all-rigid metal

exhaust duct.

Exhaust Length Calculation:
1. Determine the number of 90º turns needed for

your installation.

2. The maximum length of 4

′ rigid (aluminum or

galvanized) duct which can be tolerated is shown
in the table.

A turn of 45º or less may be ignored. Two 45º
turns within the duct length should be treated
as a 90º elbow.

A turn over 45º should be treated as a 90º elbow.

CAUTION:

For personal safety, do not

terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic,
since the accumulated lint could create a fire hazard
or moisture could cause damage. Never terminate
the exhaust into a common duct or plenum with a
kitchen exhaust, since the combination of lint and
grease could create a fire hazard.

Exhaust ducts should be terminated in a dampered
wall cap to prevent back drafts, bird nesting, etc.
The wall cap must also be located at least 12

″

above the ground or any other obstruction with
the opening pointed down.

Other terminations, such as louvered wall boxes,
are acceptable provided they are equivalent to
a 4

″ opening dampered wall cap.

For more information on venting kits and
accessories, please call 1.800.GE.CARES.

Best Performance

Maximum Length

of a 4

″ Dia.

Rigid Metal Duct

Exhaust Hood Type

Number of

A

B

90º Turns

4

″ Opening

2-1/2

″ Opening

Front-Loading Dryers

0

90 ft.

60 ft.

1

60 ft.

45 ft.

2

45 ft.

35 ft.

3

35 ft.

25 ft.

4”

4”

2-1/2”

Advertising