NOTE: When mounting a salamander over an existing range

in the field, an independent fussed connection must be

made though the knock out plate provided in the main back

of the salamander .

Assembly of Backguard/High Shelf

The back guard or high shelf will have been shipped

separately . To install, put the backguard/high self on the rear

of the range, slipping the uprights into the opening on each

burner box side . Fasten the upright to the burner box side

with four hex fasteners provided .

Code Requirements

The Garland S/SS680 series complies with the standards CSA

C22 .2 no .109 – latest edition, the UL197 – latest edition and

the NSF#4 – latest edition . The installation and connection

of this appliance must comply with current codes . In Canada

– The Canadian Electrical Code Part 1 and in the USA – The

National Electrical Code .

The Garland SU680 series complies with the essential

requirements of the Directives 73/23/EEC, 89/336/EEC,

89/392/EEC, 93/68/EEC and the standards, EN60335,

IEC801 .2, IEC801 .3, IEC801 .4, IEC801 .5, IEC801 .6 and

IEC801 .11 .

Electrical Supply

Before attempting the electrical connection, the rating plate

should be checked to ensure that the equipment’s electrical

characteristics and supply electrical characteristics agree . On

ranges and salamanders the supply entrance is located at the

rear or alternatively on the main bottom . The supply terminal

block is accessible from the front . The electrical supply must

be adequate for the voltage, phase, and current marked on

the rating plate .

INSTALLATION Continued

NOTE: A means of disconnection from the supply having

a contact separation of at least 3 mm in all poles must be

incorporated in the fixed wiring .

This equipment is intended to be installed with fixed

permanent wiring .

WARNING: This appliance must be grounded .

Single And Three Phase Connection

Unless otherwise noted, all ranges are shipped from the

factory for three phase connection . Salamanders are shipped

from the factory for single phase connection . A wiring

diagram is attached to the rear of each appliance . Visually

check all electrical connections . The range is wired at the

factory as specified on the order . If it is necessary to change

the phasing refer to the wiring diagram .

Commissioning

Ensure all circuit breakers located in the lower compartment

are set to the ON (1) position

1 . Ensure that all controls are in the OFF position and turn

on the main electrical supply .

2 . Operate each section of the range or salamander in

accordance with the instructions given in the Operating

Instructions .

3 . Check that the product functions correctly and that the

voltage supply to the unit does not drop more than 5%

when all sections are operated simultaneously .