Maintenance and cleaning continued – Garland SS680 User Manual

Page 17

Advertising
background image

Part # P153 Rev 1 (02/21/08)

Page 17

4 . Carefully remove the thermostat dial, not disturbing the

dial setting .

5 . Hold the thermostat shaft steady with a small flat blade

screw driver . Turn the calibration screw located inside the

shaft clockwise to decrease the temperature and counter

clockwise to increase the temperature . NOTE: each ¼ turn

of the screw will create a change of approximately 35° F

(20°C) .

6 . Replace the thermostat dial and repeat steps 1 though 3

to verify that the correct adjustment has been made .

Dial Shaft

Calibration Screw Head

Calibration

Screw Head

Increase

Decrease

1/4" Turn

MAINTENANCE AND CLEANING Continued

Griddle

1 . Use a test instrument with a special disc type

thermocouple or a reliable surface type pyrometer . NOTE:

a drop of oil on the face of the disc will provide better

contact with the plate .

2 . Set all griddle thermostats to 350°F (177°C) . In order

to allow the griddle temperature to stabilize, the

thermostats must be allowed to cycle twice before taking

a test reading .

3 . Check the griddle temperature when the thermostat just

cycles “OFF” by placing the thermocouple firmly on the

griddle directly about the sensing bulb of the thermostat .

The reading should be between 335° F (168°C) and 365°

F and (185°C) . If the reading is outside of these limits,

calibrate as follows:

4 . Carefully remove the dial, not disturbing the shaft

position .

5 . Hold the shaft steady and with a small flat screw

driver turn the calibration screw located inside the

shaft clockwise to decrease temperature and counter

clockwise to increase temperature . NOTE: Each ¼ turn

of the screw will create a change of approximately 35° F

(20°C) .

6 . Replace the thermostat dial and repeat steps 1 through 3

verify that a correct adjustment has been made .

Advertising