Installation – Garland SS680 User Manual

Page 9

Advertising
background image

Part # P153 Rev 1 (02/21/08)

Page 9

INSTALLATION

This equipment must be installed by a competent factory

trained, certified, licensed and / or authorized service

or installation person . Electrical work must be installed

by a qualified person as required by the local electrical

authorities .

WARNING: This appliance must be grounded .

CAUTION: Prior to installation check the electrical supply to

ensure the input voltage and phase match the equipment

voltage rating and phase as shown on the rating plate .

Clearances

The space in which the appliance is to be positioned must

include the minimum installation clearances to combustible

surfaces .

MINIMUM INSTALLATION CLEARANCES

Clearance To Combustible Material

Location

Models

Ranges

Ranges

c/w Hot Top Salamander

Top

*

*

*

Sides

3” (76mm)

10” (254mm)

7” (178mm)

Rear

2” (51mm)

2” (51mm)

2” (51mm)

* NOTE: Garland recommends equipment be installed under

a ventilation canopy

LOCATION

Models

Type Of Floor Or Base

Ranges

Combustible

Ranges c/w Hot Top

Combustible

Salamander

Non-Combustible

IMPORTANT: For ranges with convention oven (models with

suffix “RC”), air circulation is required for proper operation of

the fan motors . Allow 1” (25mm) rear clearance for ventilation

of the motor .

Adequate clearance must be provided for servicing,

ventilation and proper operation . The range must be kept

clear of combustible material .

Positioning

The range should be installed on a firm, smooth and level

floor designed to withstand the weight of the fully laden

appliance .

Place the range or salamander in desired position and level

from side to side and back to front and diagonally . This

leveling must be done with the unit under the hood and in

it’s normal operating position . If the range is to be dais or

cove mounted, the base on which it is to be set should be

level . If it is not, the range must be shimmed to level .

Legs

All ranges are shipped from the factory with legs installed

unless otherwise specified . When the range is specified for

dais or cove base mounting, it is shipped less legs . Legs must

be adjusted to a minimum height of 6” (152mm) in order to

comply with NSF standards .

Casters

1 . The front casters on the unit are equipped with brakes to

limit the movement of the range without depending on

the electrical connection to limit appliance movement .

2 . A restraint can be attached to the unit near the electric

connection . If the restraint is disconnected, be sure to

reconnect it after the range has been returned to its

originally installed position .

Ventilation Air

The area in which the appliance is installed must be

adequately ventilated to provide air for removal of steam,

heat generated by the appliance, etc . These products are

recommended to be installed under a ventilation hood .

Proper operation of exhaust fans (proper speed, rotation and

adjustment) is essential . The hood, and the filters must be

cleaned on a regular bases and kept grease free .

Installation Of Range Mount Salamander

1 . The rear of the range must be easily accessible .

2 . Place the salamander in position on the range . Slide the

uprights into the opening at the oven rear . Secure the

salamander uprights to the range with the hex head bolts

provided .

3 . Remove the terminal block access cover

4 . Pass the wires though cable entrance hole .

5 . Secure the cable connector

6 . Terminate the salamander wire at the terminal block

provided (Red to L1, Black to L2 or N, Green to GRN or E) .

Advertising